Catalyst 2900 Series XL Hardware Installation Guide April 2001 Corporate Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.
Enterprise/Solver, EtherChannel, EtherSwitch, FastHub, FastSwitch, IOS, IP/TV, LightStream, MICA, Network Registrar, Post-Routing, Pre-Routing, Registrar, StrataView Plus, Stratm, SwitchProbe, TeleRouter, and VCO are registered trademarks of Cisco Systems, Inc. or its affiliates in the U.S. and certain other countries. All other brands, names, or trademarks mentioned in this document or Web site are the property of their respective owners.
C O N T E N T S Preface xi Audience xi Purpose xi Organization xii Conventions xii Related Publications xvi Obtaining Documentation xvii World Wide Web xvii Cisco Documentation CD-ROM xvii Ordering Documentation xviii Documentation Feedback xviii Obtaining Technical Assistance xix Cisco.
Contents Expansion Slots 1-8 LEDs 1-9 System LED 1-11 RPS LED 1-12 Port LEDs and Modes 1-13 Expansion Slot LEDs 1-17 Rear-Panel Description 1-18 Power Connectors 1-19 Internal Power Supply Connector 1-19 Cisco RPS Connector 1-19 Console Port 1-21 CHAPTER 2 Installation 2-1 Preparing for Installation 2-1 Warnings 2-1 EMC Regulatory Statements 2-4 U.S.A.
Contents Installing the Switch on a Wall 2-22 Attaching the Brackets to the Switch 2-22 Mounting the Switch to a Wall 2-23 Powering On the Switch and Running POST 2-25 Connecting to a 10/100 Port 2-26 Connecting to a 100BASE-FX Port 2-28 Connecting to an LRE Port 2-30 Connecting to a Module Port 2-33 Connecting to the Console Port 2-33 Where to Go Next 2-34 CHAPTER 3 Troubleshooting 3-1 Understanding POST Results 3-2 Correcting Module POST Failures 3-3 Diagnosing Problems 3-3 APPENDIX A Technical Spe
Contents Identifying a Rollover Cable B-6 Connecting to a PC B-6 Connecting to a Terminal B-7 APPENDIX C Translated Safety Warnings C-1 Attaching the Cisco RPS (model PWR600-AC-RPS) C-2 Attaching the Cisco RPS (model PWR300-AC-RPS-N1) C-3 Qualified Personnel Warning C-4 Installation Warning C-5 Jewelry Removal Warning C-6 Stacking the Chassis Warning C-8 Main Disconnecting Device C-9 Overtemperature Warning C-10 TN Power Warning C-13 Ground Connection Warning C-14 Circuit Breaker (15A) Warning C-15 Grou
Contents No On/Off Switch Warning C-27 Chassis Warning—Rack-Mounting and Servicing C-29 INDEX Catalyst 2900 Series XL Hardware Installation Guide 78-6461-03 ix
Contents Catalyst 2900 Series XL Hardware Installation Guide x 78-6461-03
Preface Audience This guide is for the networking or computer technician responsible for installing and configuring a Catalyst 2900 series XL switch. We assume that you are familiar with the concepts and terminology of Ethernet and local area networking. Purpose The Catalyst 2900 Series XL Hardware Installation Guide documents the hardware features of Catalyst 2900 series XL switches.
Preface Organization Organization This guide is organized into the following chapters: Chapter 1, “Product Overview,” summarizes the switch features, and describes the ports, the standards they support, and the LEDs. Chapter 2, “Installation,” provides the procedures for installing a switch in a rack, on a desk, or on a wall. Chapter 3, “Troubleshooting,” describes how to identify and resolve some of the problems that might arise when you are installing the switch.
Preface Conventions Notes, cautions, and warnings use the following conventions and symbols: Note Means reader take note. Notes contain helpful suggestions or references to materials not contained in this manual. Caution Means reader be careful. In this situation, you might do something that could result in equipment damage or loss of data. Warning This warning symbol means danger. You are in a situation that could cause bodily injury.
Preface Conventions Attention Ce symbole d’avertissement indique un danger. Vous vous trouvez dans une situation pouvant entraîner des blessures. Avant d’accéder à cet équipement, soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les procédures courantes de prévention des accidents. Pour obtenir les traductions des mises en garde figurant dans cette publication, veuillez consulter l’annexe intitulée C « Translated Safety Warnings » (Traduction des avis de sécurité).
Preface Conventions Aviso Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar danos fisicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se com os perigos relacionados com circuitos eléctricos, e com quaisquer práticas comuns que possam prevenir possíveis acidentes. (Para ver as traduções dos avisos que constam desta publicação, consulte o apêndice C “Translated Safety Warnings” “Traduções dos Avisos de Segurança”).
Preface Related Publications Related Publications You can order printed copies of documents with a DOC-xxxxxx= number. The following publications provide more information about the switches: • Release Notes for the Catalyst 2900 Series XL and Catalyst 3500 Series XL, Cisco IOS Release 12.0(5)WC(1) • Catalyst 2900 XL and Catalyst 3500 XL Documentation CD Note This product-specific CD contains only the Catalyst 2900 XL and Catalyst 3500 XL switch documents and related hardware documents.
Preface Obtaining Documentation – Cisco 575 LRE CPE Hardware Installation Guide (order number DOC-7811469=) • Installation Notes for the Cisco LRE 48 POTS Splitter (order number DOC-7812250=) Obtaining Documentation The following sections provide sources for obtaining documentation from Cisco Systems. World Wide Web You can access the most current Cisco documentation on the World Wide Web at the following sites: • http://www.cisco.com • http://www-china.cisco.com • http://www-europe.cisco.
Preface Obtaining Documentation Ordering Documentation Cisco documentation is available in the following ways: • Registered Cisco Direct Customers can order Cisco Product documentation from the Networking Products MarketPlace: http://www.cisco.com/cgi-bin/order/order_root.pl • Registered Cisco.com users can order the Documentation CD-ROM through the online Subscription Store: http://www.cisco.
Preface Obtaining Technical Assistance Obtaining Technical Assistance Cisco provides Cisco.com as a starting point for all technical assistance. Customers and partners can obtain documentation, troubleshooting tips, and sample configurations from online tools. For Cisco.com registered users, additional troubleshooting tools are available from the TAC website. Cisco.com Cisco.
Preface Obtaining Technical Assistance Contacting TAC by Using the Cisco TAC Website If you have a priority level 3 (P3) or priority level 4 (P4) problem, contact TAC by going to the TAC website: http://www.cisco.com/tac P3 and P4 level problems are defined as follows: • P3—Your network performance is degraded. Network functionality is noticeably impaired, but most business operations continue.
C H A P T E R 1 Product Overview This chapter provides the following topics that describe the Catalyst 2900 series XL switches, hereafter referred to as the switches. • Switch features, including management options • Descriptions of the front and rear panels • Descriptions of the LEDs Features The switches are stackable 10/100 Ethernet switches to which you can connect workstations, Cisco IP Phones, and other network devices such as servers, routers, and other switches.
Chapter 1 Product Overview Features • On the Catalyst 2924M XL and Catalyst 2912MF XL switches, two expansion slots for 10BASE-T/100BASE-TX, 100BASE-FX, Gigabit Ethernet, and asynchronous transfer mode (ATM) modules • On the Catalyst 2912 LRE XL and 2924 LRE XL switches, up to 24 LRE ports through one RJ-21 connector • Supports up to 2048 MAC addresses on the Catalyst 2924 XL, 2924C XL, and 2912 XL switches • Supports up to 8192 MAC addresses on the Catalyst 2924M XL and 2912MF XL switches Figure
Chapter 1 Product Overview Features Figure 1-1 Catalyst 2900 Series XL Switches Version Number Description WS-C2912-LRE-XL 4 fixed autosensing 10/100 ports 12 LRE ports WS-C2924-LRE-XL WS-C2912-XL INPUT PWR OUTPUT PWR RESET 9X TEMP 10X 11X FAN 12X Cisco RPS 300 4 fixed autosensing 10/100 ports 24 LRE ports INPUT PWR OUTPUT PWR RESET 9X TEMP 10X 11X FAN 12X Cisco RPS 300 12 fixed autosensing 10/100 ports 1X 2X 3X 4X MODE 5X 6X 7X 8X 10BaseT/ 9X 100BASE 10X -TX 11X 12X
Chapter 1 Product Overview Features Management Interface Options The Catalyst 2900 XL and Catalyst 3500 XL switches are designed for plug-and-play operation: you only need to assign basic IP information to the switch and connect it to the other devices in your network. If you have specific network needs, you can configure and monitor the switch—on an individual basis or as part of a switch cluster—through its various management interfaces.
Chapter 1 Product Overview Front-Panel Description Front-Panel Description Depending on the model, the switch front panels can have up to 24 10/100 ports (See Figure 1-2), up to 12 100BASE-FX ports (See Figure 1-2), 2 expansion slots (see Figure 1-2), and up to 24 Long-Reach Ethernet ports (See Figure 1-4). All switches have a set of LEDs and a Mode button. This section describes these front-panel components.
Chapter 1 Product Overview Front-Panel Description Figure 1-4 Catalyst 2900 LRE XL 10/100 and LRE Ports INPUT PWR OUTPUT PWR RESET TEMP 9X FAN 10X 11X 12X 48005 Catalys t 2900 LR E XL 10/100 ports LRE ports 10/100 Ports The 10/100 switch ports (see Figure 1-2 and Figure 1-4) can connect to any compatible network device up to 328 feet (100 meters) away: Note • 10BASE-T-compatible devices, such as workstations, Cisco IP Phones, and hubs through standard RJ-45 connectors and Category 3, 4, or
Chapter 1 Product Overview 100BASE-FX Ports The 10/100 ports on the Catalyst 2900 XL switches provide protocol support for Cisco IP Phones and per-port priority override. Refer to the Catalyst 2900 Series XL and Catalyst 3500 Series XL Software Configuration Guide for more information about these features. Cisco IP Phones—connected to the 10/100 port—must be connected to an AC power source. Unlike the 3524-PWR XL switch, the Catalyst 2900 XL switches do not provide inline power.
Chapter 1 Product Overview 100BASE-FX Ports If telephone services, such as voice or integrated services digital network (ISDN), use the same cabling as LRE traffic, the LRE port must be connected to the patch panel through a basic telephone service, also known as plain old telephone service (POTS) splitter.
Chapter 1 Product Overview 100BASE-FX Ports Table 1-1 Expansion Modules (continued) Module Type Model Number 1 WS-X2931-XL Ethernet Gigabit ATM WS-X2971-XL WS-X2972-XL WS-X2951-XL WS-X2961-XL 1. Accommodates modules WS-G5484 =, WS-G5486 =, and WS-X3500-XL= These modules automatically configure themselves when you insert them in expansion slots and tighten the thumb screws. A power-on self-test (POST) verifies that the module is working properly before it starts forwarding packets.
Chapter 1 Product Overview 100BASE-FX Ports Figure 1-5 Catalyst 2912 XL, 2924 XL, and 2924C XL LEDs 10/100 port LEDs System LED Port mode LEDs 1X 2X 3X 4X Mode button Figure 1-6 5X 6X 7X 47288 MODE RPS LED Catalyst 2912MF XL and 2924M XL LEDs 10BASE-FX port LEDs 1 2 1 2 MODE 3 4 100BAS 5 E-FX 6 48003 7 System LED RPS LED Expansion slot status LED Port mode LED Mode button Catalyst 2900 Series XL Hardware Installation Guide 1-10 78-6461-03
Chapter 1 Product Overview 100BASE-FX Ports Figure 1-7 Catalyst 2912 LRE XL and 2924 LRE XL LEDs 10/100 port LEDs SYSTEM RPS LRE STAT DUPLX SPEED Mode button 1X 2X 3X 4X System LED RPS LED LRE LED STAT LED DUPLEX LED Speed LED 48002 MODE LRE port LEDs 1-12 LRE port LEDs 13-24 System LED The system LED shows whether the system is receiving power and functioning properly. Table 1-2 lists the LED colors and their meanings.
Chapter 1 Product Overview 100BASE-FX Ports RPS LED The Catalyst 2912 LRE XL, Catalyst 2924 LRE XL, and Catalyst 3524-PWR XL switches use the Cisco RPS 300 (model PWR300-AC-RPS-N1). All other Catalyst 2900 XL and Catalyst 3500 XL switches use the Cisco RPS 600 (model PWR600-AC-RPS). Refer to the appropriate switch documentation for redundant power system (RPS) descriptions specific for the switch. Table 1-3 and Table 1-4 list the RPS LED colors and their meanings.
Chapter 1 Product Overview 100BASE-FX Ports Table 1-4 RPS LED on the Catalyst 2912 LRE XL and 2924 LRE XL Switches (continued) Color RPS Status Solid amber RPS is connected but not functioning properly. Blinking amber • The RPS could be in standby mode. Pressing the Standby/Active button the RPS puts it in Active mode, and the LED should turn green. • One of the power supplies in the RPS could be powered down. • A fan in the RPS might have failed.
Chapter 1 Product Overview 100BASE-FX Ports Table 1-6 Meanings of Port Status LED Colors for Different Modes on Catalyst 2912 LRE XL and 2924 LRE XL Switches Mode LED Port Mode Description LRE LRE link status Long-Reach Ethernet (LRE) link status of the LRE ports on the Catalyst 2912 LRE XL and Catalyst 2924 LRE XL switches. Default mode on these switches only.
Chapter 1 Product Overview 100BASE-FX Ports Table 1-7 Meanings of Port Status LED Colors for Different Modes on Catalyst 2912 XL, 2924C XL, 2924 XL, 2924MF XL, and 2924M XL Switches Port Mode Port LED Color Meaning STAT (port status) Off No link. Solid green Link present. Flashing green Activity. Port is transmitting or receiving data. Alternating green-amber Link fault.
Chapter 1 Product Overview 100BASE-FX Ports Table 1-8 Meanings of Port Status LED Colors for Different Modes on Catalyst 2912 LRE XL and 2924 LRE XL Switches Port Mode Port LED Color Meaning LRE Off No LRE link present on the LRE port. Green LRE link present on the LRE port. Port LED turns green within 10 seconds after the LRE port detects a connection to a Cisco 575 LRE CPE. Amber LRE port and WAN CPE port unable to establish the rate defined by the assigned profile.
Chapter 1 Product Overview 100BASE-FX Ports Figure 1-8 Bandwidth Utilization Catalyst 2900 SERIES XL 10BaseT/100BaseTx RPS 1x 2x 3x 4x 5x 6x 7x 8x 9x 10x 11x 12x 47293 SYSTEM MODE 6.25 –12.4%+ 12.5 –24%+ 25 – 49%+ 50%+ Expansion Slot LEDs Expansion slot LEDs (shown in Figure 1-6) show the status of installed modules. The LEDs are numbered 1 (left slot) and 2 (right slot). Table 1-9 lists LED colors and their meanings.
Chapter 1 Product Overview Rear-Panel Description Rear-Panel Description The switch rear panels have an AC power connector, an RPS connector, and an RJ-45 console port (see Figure 1-10, Figure 1-10, and Figure 1-11), which are described in this section. Figure 1-9 Catalyst 2912 XL, 2924 XL, and 2924C XL Rear Panel Fans RATING 100-127/ 200-240V~ 1.0A/O.5 A 50-8 0HZ DC INPU TS FOR REMOTE POWER SUPPLY SPECIFI ED IN +5V MANUAL @9A, +12V @0.
Chapter 1 Product Overview Rear-Panel Description Figure 1-11 Catalyst 2912 LRE XL and 2924 LRE XL Rear Panel 100-240 MAXIMU M 300 W TOTAL OUTPUT 48004 V~ 5-3A 50/60Hz DC OUT PUT AC power connector CONSOL E Redundant power system connector RJ-45 connector Power Connectors You can provide power to the switch either through the internal power supply or through the Cisco RPS.
Chapter 1 Product Overview Rear-Panel Description RPS Connector on the Catalyst 2912 XL, 2924C XL, 2924 XL, 2924MF XL, and 2924M XL Switches The Cisco RPS 600 (model PWR600-AC-RPS) provides a quasi-redundant power source for four external devices that use up to 150W DC each. Use a one-to-one cable (one connector at each cable end) to connect four external devices to the four DC output power modules.
Chapter 1 Product Overview Rear-Panel Description Note The RPS can only power one switch at a time. If more than one switch fails at the same time, any subsequent switch is not supported by the RPS until the first switch failure is resolved. For more information on the Cisco RPS 300, refer to the Cisco Redundant Power System 300 Hardware Installation Guide. Console Port You can connect a switch to a PC through the switch console port and by using the supplied rollover cable and DB-9 adapter.
Chapter 1 Product Overview Rear-Panel Description Catalyst 2900 Series XL Hardware Installation Guide 1-22 78-6461-03
C H A P T E R 2 Installation This chapter describes how to install your Catalyst 2900 XL switch and interpret the power-on self-test (POST) that ensures proper operation.
Chapter 2 Installation Preparing for Installation Warning Only trained and qualified personnel should be allowed to install or replace this equipment. Warning Read the installation instructions before you connect the system to its power source. Warning Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces, and watches).
Chapter 2 Installation Preparing for Installation Warning This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 15A U.S. (240 VAC, 10A international) is used on the phase conductors (all current-carrying conductors). Warning This equipment is intended to be grounded. Ensure that the host is connected to earth ground during normal use.
Chapter 2 Installation Preparing for Installation Warning Invisible laser radiation may be emitted from the aperture ports of the 100BASE-FX single-mode supervisor engine module. Avoid exposure and do not stare into open apertures. Warning Avoid exposure to the laser beam. Warning Attach only the Cisco RPS (model PWR600-AC-RPS) to the RPS receptacle. Warning Attach only the Cisco RPS (model PWR300-AC-RPS-N1) to the RPS receptacle. EMC Regulatory Statements U.S.A. U.S.
Chapter 2 Installation Preparing for Installation Hungary This equipment is a class A product and should be used and installed properly according to the Hungarian EMC Class A requirements (MSZEN55022). Class A equipment is designed for typical commercial establishments for which special conditions of installation and protection distance are used.
Chapter 2 Installation Preparing for Installation • For LRE ports, cable lengths from the switch to the connected Ethernet device are up to 4921 feet (1500 meters). • Cabling is away from sources of electrical noise, such as radios, power lines, and fluorescent lighting fixtures. • For specifications of the expansion modules, refer to the modules documentation in the “Related Publications” section on page xvi.
Chapter 2 Installation Installing the Switch on a Table or Shelf • Mounting kit containing these items: – Four rubber feet for mounting the switch on a table, shelf, or desk – Two mounting brackets – Four number-12 Phillips machine screws for attaching the brackets to a rack – Four number-8 Phillips flat-head screws for attaching the brackets to the switch (19-inch rack mount) – Four number-8 Phillips truss-head screws for attaching the brackets to the switch (24-inch rack mount) – One cable guide and
Chapter 2 Installation Installing the Switch in a Rack Installing the Switch in a Rack Warning To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety: • This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
Chapter 2 Installation Installing the Switch in a Rack Figure 2-1 Mounting Bracket Points for Catalyst 2912 XL, 2924C XL, 2924 XL, 2912MF XL, or 2924M XL Switches 24" rack mount point 23" rack mount point 19" rack mount point 24" rack mount point 23" rack mount point Figure 2-2 Mounting Brackets Points for Catalyst 2912 LRE XL and 2924 LRE XL Switches 19" rack mount point 24" rack mount point 23" rack mount point 19" rack mount point 24" rack mount point 23" rack mount point 54725 47307 1
Chapter 2 Installation Installing the Switch in a Rack To install the switch in a 19-, 23- or 24-inch standard rack, follow the instructions described in these procedures: • “Removing Screws from the Switch” section on page 2-10 • “Attaching the Brackets to a Catalyst 2912 XL, 2924C XL, 2924 XL, 2912MF XL, or 2924M XL Switch” section on page 2-11 • “Attaching the Brackets to a Catalyst 2912 LRE XL or 2924 LRE XL Switch” section on page 2-17 • “Mounting the Switch in a Rack” section on page 2-19 •
Chapter 2 Installation Installing the Switch in a Rack Attaching the Brackets to a Catalyst 2912 XL, 2924C XL, 2924 XL, 2912MF XL, or 2924M XL Switch Follow these steps to attach the brackets to a Catalyst 2912 XL, 2924C XL, 2924 XL, 2912MF XL, or 2924M XL switch: The bracket orientation and screws that you use depend on whether you are attaching the brackets for a 19-, 23-, or 24-inch rack.
Chapter 2 Installation Installing the Switch in a Rack Figure 2-4 Attaching Brackets on Catalyst 2912 XL, 2924C XL, 2924 XL Fixed-Port Switches (Front-Panel Forward) Phillips flat-head screws 1X 19" configuration 2X 3X MODE 4X 5X 6X 7X 1X 23" and 24" configuration MODE 2X 3X 4X 5X 6X 47738 Phillips truss-head screws 7X Catalyst 2900 Series XL Hardware Installation Guide 2-12 78-6461-03
Chapter 2 Installation Installing the Switch in a Rack Figure 2-5 Attaching Brackets on Catalyst 2912MF XL and 2924M XL Modular Switches (Front-Panel Forward) Phillips flat-head screws 1 2 1X 19" configuration 2X 3X 4X MODE 5X 6X 7X Phillips truss-head screws 2 1X 23" and 24" configuration MODE 2X 3X 4X 5X 6X 7X 47297 1 Catalyst 2900 Series XL Hardware Installation Guide 78-6461-03 2-13
Chapter 2 Installation Installing the Switch in a Rack Figure 2-6 Attaching Brackets on Catalyst 2912 XL, 2924C XL, 2924 XL Fixed-Port Switches (Rear-Panel Forward) Phillips flat-head screws 19" configuration 23" and 24" configuration 47298 Phillips truss-head screws Catalyst 2900 Series XL Hardware Installation Guide 2-14 78-6461-03
Chapter 2 Installation Installing the Switch in a Rack Figure 2-7 Attaching Brackets on Catalyst 2912MF XL and 2924M XL Modular Switches (Rear-Panel Forward) Phillips flat-head screws RATING 100-120 /200-240 ~ 2.0A/1.0 V A 50-6 0HZ DC INP UT 19" configuration Phillips truss-head screws RATING 100-120 /200-240 ~ 2.0A/1.
Chapter 2 Installation Installing the Switch in a Rack Figure 2-8 Attaching Brackets for Telco Racks Phillips flat-head screws RATING 100-120 /200-240 ~ 2.0A/1.0 V A 50-6 0HZ Phillips flat-head screws Note 52532 DC INP UT Catalyst 2912 LRE XL and 2924 LRE XL switches cannot be mounted in telco racks.
Chapter 2 Installation Installing the Switch in a Rack Attaching the Brackets to a Catalyst 2912 LRE XL or 2924 LRE XL Switch Follow these steps to attach the brackets to a Catalyst 2912 LRE XL or 2924 LRE XL switch: The bracket orientation and screws that you use depend on whether you are attaching the brackets for a 19-, 23-, or 24-inch rack.
Chapter 2 Installation Installing the Switch in a Rack Figure 2-9 Attaching Brackets on Catalyst 2912 LRE XL and 2924 LRE XL Switches (Front-Panel Forward) Phillips flat-head screws INPUT PWR OUTPUT PWR RESET TEMP FAN 9X 10X 11X 19" configuration 12X Phillips truss-head screws INPUT PWR OUTPUT PWR RESET TEMP FAN 9X 10X 11X 12X 54728 23" and 24" configuration Catalyst 2900 Series XL Hardware Installation Guide 2-18 78-6461-03
Chapter 2 Installation Installing the Switch in a Rack Figure 2-10 Attaching Brackets on Catalyst 2912 LRE XL and 2924 LRE XL Switches (Rear-Panel Forward Phillips flat-head screws 19" configuration 23" and 24" configuration 54824 Phillips truss-head screws Mounting the Switch in a Rack After the brackets are attached to the switch, use the four supplied number-12 Phillips machine screws to securely attach the brackets to the rack, as shown in Figure 2-11.
Chapter 2 Installation Installing the Switch in a Rack Figure 2-11 Mounting the Switch in a Rack 1X 2X 3X MODE 4X 5X 6X 7X 8X 9X 10BaseT/1 10X 11X 12X 00Ba100B seTXaseFX 13X 14X 16X 17X 18X 19X 20X Catalyst 2900 SERIES 21X 22X 23X XL 24X Phillips machine screws 2 1X MODE 2X 3X Catalyst 2900 SERIES 4X 5X 6X 7X 8X 9X 100BaseF 10X 11X 12X 13X XL X 14X 15X 16X 17X 18X 19X 20X 47301 1 21X 22X 23X 24X Phillips machine screws After the switch is mounted in the
Chapter 2 Installation Installing the Switch in a Rack The cable guide is not applicable for the Catalyst 2912 LRE XL and 2924 LRE XL switches.
Chapter 2 Installation Installing the Switch on a Wall Installing the Switch on a Wall To attach the switch to a wall, follow the procedures in this section: Note • Attaching the brackets to the switch • Attaching the switch to a wall To mount a Catalyst 2912 LRE XL or 2924 LRE XL switch on a wall, you need to obtain two special wall-mount brackets (Cisco part number wallmount-1ru=). To order these brackets, contact your Cisco sales representative.
Chapter 2 Installation Installing the Switch on a Wall Phillips truss-head screws 47303 Figure 2-13 Attaching Brackets for Parallel and Vertical Wall-Mounting for Fixed-Port Switches Figure 2-14 Attaching Brackets for Parallel and Vertical Wall-Mounting for Modular Switches RATING 100-120 /200-240 ~ 2.0A/1.
Chapter 2 Installation Installing the Switch on a Wall Figure 2-15 Mounting a Fixed-Port Switch to a Wall SERIES Vertical wall stud 13x 12x 47305 RPS MODE 1x 2x 3x 4x 5x 6x 7x 8x 9x 10x 11x 10BaseT/100BaseTx 14x 15x 16x 17x 18x 19x 20x 21x 22x 23x 24x User-supplied screws Catalyst 2900 Series XL Hardware Installation Guide 2-24 78-6461-03
Chapter 2 Installation Powering On the Switch and Running POST Figure 2-16 Mounting a Modular Switch to a Wall Vertical wall stud 16x 15x 14x 13x 11x 10BaseT/100BaseTX 8x 13x 7x 12x Vertical wall-mount Parallel wall-mount 47306 MODE 1x 2x 3x 4x 5x MODE 6x 1x 7x 2x 8x 3x 9x 4x 5x 10x 6x 11x 10BaseT/100BaseTX 9x 14x 10x 15x 16x 17x 18x 19x User-supplied screws 12x 20x 17x 21x 18x 22x 19x 23x 20x 24x 21x 22x 23x 24x SERIES SERIES User-supplied screws A
Chapter 2 Installation Connecting to a 10/100 Port The System LED flashes green, and the RPS LED turns off. As each test runs, the port LEDs, starting with number 1, turn off. The port LEDs for ports 2 to 8 each turn off in turn as the system completes a test. When POST completes successfully, the port LEDs return to the status mode display, indicating that the switch is operational. If a test fails, the port LED associated with the test turns amber, and the system LED turns amber.
Chapter 2 Installation Connecting to a 10/100 Port Follow these steps to connect to 10BASE-T and 100BASE-TX devices: Step 1 When connecting to workstations, servers, routers, and Cisco IP Phones, connect a straight-through Category 5 cable to an RJ-45 connector on the front panel (Figure 2-17). When connecting to switches or repeaters, use a crossover Category 5 cable. Pinouts for the cables are described in the “Cable and Adapter Specifications” section on page B-4.
Chapter 2 Installation Connecting to a 100BASE-FX Port The port LED is amber while Spanning Tree Protocol (STP) discovers the topology and searches for loops. This takes about 30 seconds, and then the port LED turns green. If the port LED does not come on, the device at the other end might not be turned on, or there might be a cable problem or a problem with the adapter installed in the attached device. See Chapter 3, “Troubleshooting,” for solutions to cabling problems.
Chapter 2 Installation Connecting to a 100BASE-FX Port Note • If the switch port and the port on the attached device are configured for half-duplex operation, the connection can be up to 412 meters. • If the switch port and the port on the attached device are configured for full-duplex operation, the connection can be up to 2 kilometers. Speed and duplex-mode autonegotiation is not supported on the 100BASE-FX ports.
Chapter 2 Installation Connecting to an LRE Port Step 5 Reconfigure and reboot the connected device if necessary. Step 6 Repeat Steps 1 through 3 to connect each 100BASE-FX port. Connecting to an LRE Port Depending on the switch model, you can connect the LRE port to either 12 or 24 Cisco 575 LRE customer premises equipment (CPE) devices through a patch panel.
Chapter 2 Installation Connecting to an LRE Port Figure 2-19 Connecting to an LRE Port RJ-21 connector SYSTEM RPS MODE LRE STAT DUPLX SPEED 1X 2X 3X 4X Screw RJ-21 connector Screw Cable to wiring trunk RJ-21 connector SYSTEM RPS LRE STAT DUPLX SPEED 1X 2X 3X 4X 54560 MODE Screw RJ-21 connector Cable to wiring trunk 0.
Chapter 2 Installation Connecting to an LRE Port Step 2 Referring to the following figure, secure the cable to the switch: • For a 90-degree connector, see the top of Figure 2-19. • For a 12-degree connector, see the bottom Figure 2-19. Note Step 3 The cable tie is not included with the connector and cable assembly. Connect the other end of the cable to the patch panel or POTS splitter. Each LRE port status LED turns on when it establishes a link with a Cisco 575 LRE CPE.
Chapter 2 Installation Connecting to a Module Port Connecting to a Module Port For information about installing and connecting to modules in the Catalyst 2924M XL and 2912MF XL expansion slots, refer to the Catalyst 2900 Series XL Modules Installation Guide and the Catalyst 2900 Series XL ATM Modules Installation and Configuration Guide. Connecting to the Console Port Use the supplied rollover cable and DB-9 adapter to connect a PC to the switch console port.
Chapter 2 Installation Where to Go Next Step 3 Using the supplied rollover cable, connect one end of the rollover cable into the console port, as shown in Figure 2-20. See the “Identifying a Rollover Cable” section on page B-6 for a description of the pinout. Figure 2-20 Connecting to the Console Port DC INPU TS FO R REM POW OTE SPECIF ER SUPPLY IED IN +5V MANUA @24A, L. +12V @1.
C H A P T E R 3 Troubleshooting The LEDs on the front panel of the Catalyst 2900 series XL switch provide troubleshooting information about the switch. They show failures in the power-on self-test (POST), port-connectivity problems, and overall switch performance. For a full description of the switch LEDs, see the “LEDs” section on page 1-9. You can also get statistics from the browser interface, from the command-line interface (CLI), or from an SNMP workstation.
Chapter 3 Troubleshooting Understanding POST Results Understanding POST Results Each time the switch is powered on, eight POSTs run automatically to check the most important system components before the switch begins forwarding packets. When the switch begins its POST, the port status LEDs turn amber for 2 seconds, and then they turn green. As each test runs, the port status LEDs turn off, starting with number 1x.
Chapter 3 Troubleshooting Diagnosing Problems Correcting Module POST Failures If you install modules WS-X2914-XL or WS-X2922-XL in a Catalyst 2924M XL or Catalyst 2912MF XL switch, the module fails POST. This failure occurs because the expansion modules support 2048 MAC addresses and the switch supports 8192 MAC addresses. To correct the failure, restart the switch with the module installed. After the restart, the address capacity of the switch is reduced to 2048 MAC addresses.
Chapter 3 Troubleshooting Diagnosing Problems Table 3-2 Common Problems and Their Solutions Symptom Possible Cause Resolution Poor Performance or Excessive Errors. Duplex autonegotiation mismatch. Refer to the Catalyst 2900 Series XL and Catalyst 3500 Series XL Software Configuration Guide for information on identifying autonegotiation mismatches. Cabling distance exceeded. • Port statistics show excessive frame check sequence (FCS), late-collision, or alignment errors.
Chapter 3 Troubleshooting Diagnosing Problems Table 3-2 Common Problems and Their Solutions (continued) Symptom Possible Cause No Connectivity. Incorrect or bad cable. Resolution The following are indicated by no link at both ends: • A crossover cable was used when a straight-through was required or vice-versa. • For the correct pinouts and the proper application of crossover or straight-through cables, see the “Crossover and Straight-Through Cable Pinouts” section on page B-3.
Chapter 3 Troubleshooting Diagnosing Problems Table 3-2 Common Problems and Their Solutions (continued) Symptom Possible Cause LRE status LED not turned RJ-21 cable loose or not connected on. properly. LRE status LED stays amber. Resolution Reseat RJ-21 connector and fasten with screw or cable tie. Trunk cable defective. Verify trunk cable, repair or use alternate pair. CPE device absent, not powered, or defective. Check CPE device, and refer to installation guide.
A P P E N D I X A Technical Specifications Table A-1, Table A-2, Table A-3, and Table A-4 list the technical specifications for the Catalyst 2900 series switches. For switches that support modules (Catalyst 2912MF XL and 2924M XL), also refer to the Catalyst 2900 Series XL Modules Installation Guide and the Catalyst 2900 Series XL ATM Modules Installation Guide for additional specifications. Table A-5 lists the agency approvals for EMI and safety.
Appendix A Table A-1 Technical Specifications Technical Specifications for the Catalyst 2912 XL and Catalyst 2912MF XL Switches Catalyst 2912 XL Catalyst 2912MF XL Operating temperature 32 to 113°F (0 to 45°C) 32 to 113°F (0 to 45°C) Storage temperature –4 to 149°F (–10 to 65°C) –4 to 149°F (–10 to 65°C) Operating humidity 10 to 85% (noncondensing) 10 to 85% (noncondensing) Operating altitude Up to 10,000 ft (3000 m) Up to 10,000 ft (3000 m) Storage altitude Up to 15,000 ft (4570m) Up to
Appendix A Table A-2 Technical Specifications Technical Specifications for the Catalyst 2924 XL and Catalyst 2924C XL Switches Catalyst 2924 XL Catalyst 2924C XL Operating temperature 32 to 113°F (0 to 45°C) 32 to 113°F (0 to 45°C) Storage temperature –4 to 149°F (–10 to 65°C) –4 to 149°F (–10 to 65°C) Operating humidity 10 to 85% (noncondensing) 10 to 85% (noncondensing) Operating altitude Up to 10,000 ft (3000 m) Up to 10,000 ft (3000 m) Storage altitude Up to 15,000 ft (4570 m) Up to
Appendix A Table A-3 Technical Specifications Technical Specifications for the Catalyst 2924M XL Switches Environmental Operating Ranges Operating temperature 32 to 113°F (0 to 45°C) Storage temperature –4 to 149°F (–10 to 65°C) Operating humidity 10 to 85% (noncondensing) Operating altitude Up to 10,000 ft (3000 m) Storage altitude Up to 15,000 ft (4570 m) Power Requirements AC input voltage 100 to 127/200 to 240 VAC (autoranging) 50 to 60 Hz DC input voltages +5V @12A, +12V @0.
Appendix A Technical Specifications Table A-4 Technical Specifications for the Catalyst 2912 LRE XL and 2924 LRE XL Switches Environmental Operating Ranges Operating temperature 32 to 113°F (0 to 45°C) Storage temperature –13 to 158°F (–25 to 70°C) Operating humidity 10 to 85% (noncondensing) Operating altitude Up to 10,000 ft (3000 m) Storage altitude Up to 15,000 ft (4570 m) Power Requirements AC input voltage 100 to 127/200 to 240 VAC (autoranging) 50 to 60 Hz DC input voltages +12V Pow
Appendix A Technical Specifications Catalyst 2900 Series XL Hardware Installation Guide A-6 78-6461-03
A P P E N D I X B Connectors and Cable Specifications This appendix describes the Catalyst 2900 XL switch ports and the cables and adapters that you use to connect the switch to other devices. Connector Specifications 10/100 Ports The 10/100 Ethernet ports use standard RJ-45 connectors and Ethernet pinouts with internal crossovers, as shown by an X in the port name.
Appendix B Connectors and Cable Specifications Connector Specifications Pin 10/100 Port Pinouts Label 1 RD+ 2 RD- 3 TD+ 4 NC 5 NC 6 TD- 7 NC 8 NC 1 2 3 4 5 6 7 8 54968 Figure B-1 When connecting the 10/100 ports to compatible workstations, servers, routers, and Cisco IP Phones, you must use a straight-through cable wired for 10BASE-T and 100BASE-TX. (Figure B-4 shows the straight-through cable schematics.
Appendix B Connectors and Cable Specifications Connector Specifications 100BASE-FX SC Connector 47739 Figure B-2 Tx Rx LRE Ports The LRE ports use a single RJ-21 connector, as shown in Figure B-3. Figure B-3 RJ-21 Connector SYSTEM RPS LRE STAT DUPLX SPEED 1X 2X 3X 4X RJ-21 connector 48727 MODE Console Port The console port uses an 8-pin RJ-45 connector, described in Table B-2 and Table B-3.
Appendix B Connectors and Cable Specifications Cable and Adapter Specifications port to a terminal. You can order a kit (part number ACS-DSBUASYN=) containing that adapter from Cisco. For console port and adapter pinout information, see Table B-2 and Table B-3. Cable and Adapter Specifications Crossover and Straight-Through Cable Pinouts The schematics of crossover and straight-through cables are shown in Figure B-4 and Figure B-5.
Appendix B Connectors and Cable Specifications Cable and Adapter Specifications RJ-21 Cable Pinouts Note Table B-1 RJ-21 Cable Pinouts Pins Circuit Pins Circuits 1, 26 1, tip/ring 14, 39 14, tip/ring 2, 27 2, tip/ring 15, 40 15, tip/ring 3, 28 3, tip/ring 16, 41 16, tip/ring 4, 29 4, tip/ring 17, 42 17, tip/ring 5, 30 5, tip/ring 18, 43 18, tip/ring 6, 31 6, tip/ring 19, 44 19, tip/ring 7, 32 7, tip/ring 20, 45 20, tip/ring 8, 33 8, tip/ring 21, 46 21, tip/ring 9, 3
Appendix B Connectors and Cable Specifications Identifying a Rollover Cable Identifying a Rollover Cable You can identify a rollover cable by comparing the two modular ends of the cable. Hold the cable ends side-by-side, with the tab at the back. The wire connected to the pin on the outside of the left plug should be the same color as the wire connected to the pin on the outside of the right plug (see Figure B-6).
Appendix B Connectors and Cable Specifications Connecting to a Terminal Table B-2 Console Port Signaling and Cabling Using a DB-9 Adapter Console Port (DTE) RJ-45-to-RJ-45 Rollover Cable RJ-45-to-DB-9 Terminal Adapter Console Device Signal RJ-45 Pin RJ-45 Pin DB-9 Pin Signal RTS 1 8 8 CTS Not connected 2 7 6 DSR TxD 3 6 2 RxD GND 4 5 5 GND GND 5 4 5 GND RxD 6 3 3 TxD Not connected 7 2 4 DTR CTS 1 7 RTS 8 Connecting to a Terminal Use the thin, flat, RJ-45-to
Appendix B Connectors and Cable Specifications Connecting to a Terminal Table B-3 Console Port Signaling and Cabling Using a DB-25 Adapter Console Port (DTE) RJ-45-to-RJ-45 Rollover Cable RJ-45-to-DB-25 Terminal Adapter Console Device Signal RJ-45 Pin RJ-45 Pin DB-25 Pin Signal RTS 1 8 5 CTS Not connected 2 7 6 DSR TxD 3 6 3 RxD GND 4 5 7 GND GND 5 4 7 GND RxD 6 3 2 TxD Not connected 7 2 20 DTR CTS 8 1 4 RTS Catalyst 2900 Series XL Hardware Installation
A P P E N D I X C Translated Safety Warnings This appendix repeats in multiple languages the warnings in this guide. These translated warnings can be used with other documents related to this guide.
Appendix C Translated Safety Warnings Attaching the Cisco RPS (model PWR600-AC-RPS) Attaching the Cisco RPS (model PWR600-AC-RPS) This warning applies to the Catalyst 2912 XL, 2924 XL, 2924C XL, 2924M XL, and 2924C XL switches. Warning Waarschuwing: Varoitus Avertissement : Warnung: Avvertenza. Advarsel! Attach only the Cisco RPS (model PWR600-AC-RPS) to the RPS receptacle. Slechts de Cisco RPS (model PWR600-AC-RPS) aan de RPS contactdoos verbinden.
Appendix C Translated Safety Warnings Attaching the Cisco RPS (model PWR300-AC-RPS-N1) Attaching the Cisco RPS (model PWR300-AC-RPS-N1) This warning applies to the Catalyst 2912 LRE XL and 2924 LRE XL switches. Warning Waarschuwing: Varoitus Avertissement : Warnung: Avvertenza. Advarsel! Attach only the Cisco RPS (model PWR300-AC-RPS-N1) to the RPS receptacle. Slechts de Cisco RPS (model PWR300-AC-RPS-N1) aan de RPS contactdoos verbinden.
Appendix C Translated Safety Warnings Qualified Personnel Warning Qualified Personnel Warning Warning Waarschuwing Varoitus Avertissement Achtung Only trained and qualified personnel should be allowed to install or replace this equipment Installatie en reparaties mogen uitsluitend door getraind en bevoegd personeel uitgevoerd worden. Ainoastaan koulutettu ja pätevä henkilökunta saa asentaa tai vaihtaa tämän laitteen.
Appendix C Translated Safety Warnings Installation Warning Installation Warning Warning Waarschuwing Varoitus Read the installation instructions before you connect the system to its power source. Raadpleeg de installatie-aanwijzingen voordat u het systeem met de voeding verbindt. Lue asennusohjeet ennen järjestelmän yhdistämistä virtalähteeseen. Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation.
Appendix C Translated Safety Warnings Jewelry Removal Warning Jewelry Removal Warning Warning Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces, and watches). Metal objects will heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals. Waarschuwing Alvorens aan apparatuur te werken die met elektrische leidingen is verbonden, sieraden (inclusief ringen, kettingen en horloges) verwijderen.
Appendix C Translated Safety Warnings Jewelry Removal Warning Avvertenza Prima di intervenire su apparecchiature collegate alle linee di alimentazione, togliersi qualsiasi monile (inclusi anelli, collane, braccialetti ed orologi). Gli oggetti metallici si riscaldano quando sono collegati tra punti di alimentazione e massa: possono causare ustioni gravi oppure il metallo può saldarsi ai terminali.
Appendix C Translated Safety Warnings Stacking the Chassis Warning Stacking the Chassis Warning Warning Waarschuwing Varoitus Do not stack the chassis on any other equipment. If the chassis falls, it can cause severe bodily injury and equipment damage. Het chassis mag niet op andere apparatuur gestapeld te worden. Als het chassis mocht vallen, kan dit ernstig lichamelijk letsel en beschadiging van de apparatuur veroorzaken. Älä aseta asennuspohjaa minkään muun laitteen päälle.
Appendix C Translated Safety Warnings Main Disconnecting Device ¡Atención! Varning No apilar los chasis sobre ningún otro equipo. Si el chasis se cae al suelo puede causar graves lesiones físicas y daños al equipo. Placera inte chassit ovanpå annan utrustning. Om chassit faller kan allvarlig kroppsskada såväl som skada på utrustningen uppstå.
Appendix C Translated Safety Warnings Overtemperature Warning Aviso ¡Advertencia! Varning! A combinação ficha-tomada deverá ser sempre acessível, porque funciona como interruptor principal. El conjunto de clavija y toma ha de encontrarse siempre accesible ya que hace las veces de dispositivo de desconexión principal. Man måste alltid kunna komma åt stickproppen i uttaget, eftersom denna koppling utgör den huvudsakliga frånkopplingsanordningen.
Appendix C Translated Safety Warnings Overtemperature Warning Attention Pour éviter une surchauffe du commutateur, ne pas le faire fonctionner dans un local dont la température ambiante dépasse le maximum recommandé de 40°C (104 F). Pour faciliter la circulation d'air, aménager un dégagement d'au moins 7,6 cm (3 pouces) autour des bouches d'aération.
Appendix C Translated Safety Warnings Overtemperature Warning ¡Advertencia! Varning! Para evitar que el interruptor se recaliente, no se debe usar en áreas cuya temperatura ambiente exceda la máxima recomendada, esto es, 40°C (104°F). Para no entorpecer la corriente de aire, dejar por lo menos 7,6 cm (3 pulgadas) de espacio muerto alrededor de la rejilla de ventilación.
Appendix C Translated Safety Warnings TN Power Warning TN Power Warning Warning Waarschuwing The device is designed to work with TN power systems. Het apparaat is ontworpen om te functioneren met TN energiesystemen. Varoitus Koje on suunniteltu toimimaan TN-sähkövoimajärjestelmien yhteydessä. Attention Ce dispositif a été conçu pour fonctionner avec des systèmes d'alimentation TN. Warnung Das Gerät ist für die Verwendung mit TN-Stromsystemen ausgelegt.
Appendix C Translated Safety Warnings Ground Connection Warning Ground Connection Warning Warning Waarschuwing Varoitus When installing the unit, the ground connection must always be made first and disconnected last. Bij de installatie van het toestel moet de aardverbinding altijd het eerste worden gemaakt en het laatste worden losgemaakt. Laitetta asennettaessa on maahan yhdistäminen aina tehtävä ensiksi ja maadoituksen irti kytkeminen viimeiseksi.
Appendix C Translated Safety Warnings Circuit Breaker (15A) Warning Circuit Breaker (15A) Warning Warning This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 15A U.S. (240 VAC, 16A international) is used on the phase conductors (all current-carrying conductors). Waarschuwing Dit produkt is afhankelijk van de installatie van het gebouw voor kortsluit- (overstroom)beveiliging.
Appendix C Translated Safety Warnings Circuit Breaker (15A) Warning Avvertenza Questo prodotto dipende dall’installazione dell’edificio per quanto riguarda la protezione contro cortocircuiti (sovracorrente). Verificare che un fusibile o interruttore automatico, non superiore a 120 VCA, 15 A U.S. (240 VCA, 16 A internazionale) sia stato usato nei fili di fase (tutti i conduttori portatori di corrente).
Appendix C Translated Safety Warnings Grounded Equipment Warning Grounded Equipment Warning Warning Waarschuwing Varoitus This equipment is intended to be grounded. Ensure that the host is connected to earth ground during normal use. Deze apparatuur hoort geaard te worden Zorg dat de host-computer tijdens normaal gebruik met aarde is verbonden. Tämä laitteisto on tarkoitettu maadoitettavaksi. Varmista, että isäntälaite on yhdistetty maahan normaalikäytön aikana.
Appendix C Translated Safety Warnings Supply Circuit Warning Supply Circuit Warning Warning Waarschuwing Care must be given to connecting units to the supply circuit so that wiring is not overloaded. Let erop dat de toestellen op voedingscircuits worden aangesloten zonder het vermogen van de bedrading te overschrijden. Varoitus Laiteyksiköt on yhdistettävä huolellisesti syöttöpiiriin niin, että johdot eivät ole ylikuormitettuja.
Appendix C Translated Safety Warnings Voltage Warning ¡Atención! Varning Poner mucho cuidado al conectar los equipos al circuito de alimentación a fin de no sobrecargar el cableado. Var noga vid anslutning av enheter till matarströmkretsen så att ledningarna inte överbelastas. Voltage Warning Warning Waarschuwing Varoitus Avertissement Achtung A voltage mismatch can cause equipment damage and may pose a fire hazard.
Appendix C Translated Safety Warnings Voltage Warning Avvertenza Una tensione inadeguata può causare danni all'apparecchio e rischio di incendio. Se la tensione riportata sulla targhetta è diversa da quella della presa di alimentazione, non collegare lo chassis a tale presa. Advarsel Ulik spenning kan forårsake skade på utstyret og innebære brannfare. Dersom spenningen på merkelappen er forskjellig fra spenningen i stikkontakten, må du ikke koble kabinettet til den stikkontakten.
Appendix C Translated Safety Warnings Power Supply Warning Power Supply Warning Warning Do not touch the power supply when the power cord is connected. For systems with a power switch, line voltages are present within the power supply even when the power switch is off and the power cord is connected. For systems without a power switch, line voltages are present within the power supply when the power cord is connected. Waarschuwing U dient de voeding niet aan te raken zolang het netsnoer aangesloten is.
Appendix C Translated Safety Warnings Power Supply Warning Avvertenza Advarsel Aviso ¡Advertencia! Varning! Non toccare l’alimentatore se il cavo dell’alimentazione è collegato. Per i sistemi con un interruttore di alimentazione, tensioni di linea sono presenti all’interno dell’alimentatore anche quando l’interruttore di alimentazione è en posizione di disattivazione (off), se il cavo dell’alimentazione è collegato.
Appendix C Translated Safety Warnings Lightning Activity Warning Lightning Activity Warning Warning Waarschuwing Varoitus Do not work on the system or connect or disconnect cables during periods of lightning activity. Tijdens onweer dat gepaard gaat met bliksem, dient u niet aan het systeem te werken of kabels aan te sluiten of te ontkoppelen. Älä työskentele järjestelmän parissa äläkä yhdistä tai irrota kaapeleita ukkosilmalla.
Appendix C Translated Safety Warnings Product Disposal Warning ¡Advertencia! Varning! No operar el sistema ni conectar o desconectar cables durante el transcurso de descargas eléctricas en la atmósfera. Vid åska skall du aldrig utföra arbete på systemet eller ansluta eller koppla loss kablar. Product Disposal Warning Warning Waarschuwing Varoitus Ultimate disposal of this product should be handled according to all national laws and regulations.
Appendix C Translated Safety Warnings Class 1 Laser Product Warning Aviso ¡Advertencia! Varning! Deitar fora este produto em conformidade com todas as leis e regulamentos nacionais. Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales. Vid deponering hanteras produkten enligt gällande lagar och bestämmelser.
Appendix C Translated Safety Warnings Laser Beam Exposure Warning Avvertenza. Advarsel! Delle aperture delle porte del modulo apparato supervisore monomodale 100BASE-FX possono essere emesse radiazioni laser invisibili. Evitare l’esposizione diretta e non guardare nelle aperture. Usynlig laserstråling kan emitteres fra aperturutgangene til 100BASE-FX-maskinens styremodul i enkeltmodus. Unngå eksponering, og stirr ikke inn i åpne aperturer.
Appendix C Translated Safety Warnings No On/Off Switch Warning Warnung Avvertenza Advarsel Aviso ¡Advertencia! Varning! Schützen Sie sich vor Strahlung. Evitare l’esposizione al raggio. Unngå å bli utsatt for strålen. Evite exposição ao raio. Evitar la exposición al haz. Utsätt dig inte för laserstrålningen. No On/Off Switch Warning Warning Waarschuwing Varoitus Unplug the power cord before you work on a system that does not have an on/off switch.
Appendix C Translated Safety Warnings No On/Off Switch Warning Advarsel Aviso ¡Advertencia! Varning! Før det skal utføres arbeid på et system som ikke har en av/på-bryter, skal strømledningen trekkes ut. Antes de começar a trabalhar num sistema que não possua um interruptor ON/OFF, desligue o cabo de alimentação. Antes de trabajar sobre cualquier sistema que carezca de interruptor de Encendido/Apagado (ON/OFF), desenchufar el cable de alimentación.
Appendix C Translated Safety Warnings Chassis Warning—Rack-Mounting and Servicing Chassis Warning—Rack-Mounting and Servicing Warning Waarschuwing To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety: • This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
Appendix C Translated Safety Warnings Chassis Warning—Rack-Mounting and Servicing Varoitus Attention Kun laite asetetaan telineeseen tai huolletaan sen ollessa telineessä, on noudatettava erityisiä varotoimia järjestelmän vakavuuden säilyttämiseksi, jotta vältytään loukkaantumiselta. Noudata seuraavia turvallisuusohjeita: • Jos telineessä ei ole muita laitteita, aseta laite telineen alaosaan.
Appendix C Translated Safety Warnings Chassis Warning—Rack-Mounting and Servicing Warnung Avvertenza Zur Vermeidung von Körperverletzung beim Anbringen oder Warten dieser Einheit in einem Gestell müssen Sie besondere Vorkehrungen treffen, um sicherzustellen, daß das System stabil bleibt. Die folgenden Richtlinien sollen zur Gewährleistung Ihrer Sicherheit dienen: • Wenn diese Einheit die einzige im Gestell ist, sollte sie unten im Gestell angebracht werden.
Appendix C Translated Safety Warnings Chassis Warning—Rack-Mounting and Servicing Advarsel Aviso Unngå fysiske skader under montering eller reparasjonsarbeid på denne enheten når den befinner seg i et kabinett. Vær nøye med at systemet er stabilt. Følgende retningslinjer er gitt for å verne om sikkerheten: • Denne enheten bør monteres nederst i kabinettet hvis dette er den eneste enheten i kabinettet.
Appendix C Translated Safety Warnings Chassis Warning—Rack-Mounting and Servicing ¡Advertencia! Varning! Para evitar lesiones durante el montaje de este equipo sobre un bastidor, o posteriormente durante su mantenimiento, se debe poner mucho cuidado en que el sistema quede bien estable. Para garantizar su seguridad, proceda según las siguientes instrucciones: • Colocar el equipo en la parte inferior del bastidor, cuando sea la única unidad en el mismo.
Appendix C Translated Safety Warnings Chassis Warning—Rack-Mounting and Servicing Catalyst 2900 Series XL Hardware Installation Guide C-34 78-6461-03
I N D E X Numerics B 10/100BASE-T ports baud rate 2-33 cables and connectors B-1 connecting to 2-26 brackets See mounting brackets connection distances, maximum 1-6 full duplex 1-6, 1-7 half duplex 1-6 pinouts B-2 100BASE-FX ports cables and connectors B-2 C cables 10/100BASE-T ports B-1 to B-2, B-4 connecting to 2-28 to 2-30 100BASE-FX, 50/125- or 62.
Index CiscoWorks 2000 1-4 Class 1 laser product warning C-25 console port 1-21 Cluster Management Suite 1-4 adapter pinouts command-line interface (CLI) 1-4 RJ-45-to-DB-25 terminal B-7 connecting 10/100 ports to IP Phones 2-27 RJ-45-to-DB-9 terminal B-6 connecting to cable B-6 10/100BASE-T ports 2-26 connecting to 2-33 to 2-34 100BASE-FX ports 2-28 to 2-30 default characteristics 2-33 console port 2-33 to 2-34 conventions, document xii LRE port 2-30 to 2-32 crossover cable connectivity pro
Index F I feedback to Cisco Systems, web xviii installation fiber-optic cable 50/125- or 62.
Index long-reach Ethernet J See LRE jewelry removal warning C-6 LRE defined 1-1 LED 1-14, 1-16 L port connecting to 2-30 to 2-32 LAN-to-phone jack 2-27 Laser beam exposure warning C-26 See also RJ-21 connector LEDs 100 port mode 1-13, 1-15 DUPLX 1-16 expansion slots 1-17 M FDUP 1-13, 1-15 main disconnecting device warning C-9 full duplex 1-15, 1-16 maximum connection distances half duplex 1-15, 1-16 interpreting 1-13 LRE 1-14, 1-16 See connection distances, maximum mid-mount See installation
Index warning C-18 O power connectors 1-19 overtemperature warning C-10 power on 2-25 power supply AC power outlet 1-19 P RPS connector 1-19 packing list 2-6 PC, connecting to switch 2-33 warning C-21 product disposal warning C-24 performance problems, solving 3-3 personnel warning C-4 pinouts 10/100BASE-T ports B-2 Q qualified personnel warning C-4 cable, straight-through and crossover B-4 RJ-21 connector B-5 RJ-45-to-DB-25 terminal adapter B-8 RJ-45-to-DB-9 terminal adapter B-7 rollover cable B
Index RPS T LED 1-12 to 1-13 Telco 2-16 RPS 300 connector 1-20 telephone network power warning See TN power warning C-13 LED 1-13 supported switches 1-19 Telnet, and accessing the CLI 1-4 warning C-3 temperature maximum for installation 2-6, A-2 RPS 600 connector 1-20 warning C-10 LED 1-12 temperature warning C-10 supported switches 1-19 terminal, connecting to switch 2-33 warning C-2 terminal adapter pinouts RH-45-to-RJ-45 B-7 RJ-45-to-DB-25 B-7 S RJ-45-to-DB-9 B-6 safety C-1 terminal
Index voltage warning C-19 W warnings translated C-1 to C-33 Catalyst 2900 Series XL Hardware Installation Guide 78-6461-03 IN-7
Index Catalyst 2900 Series XL Hardware Installation Guide IN-8 78-6461-03