System Specifications
A-6
DC PEM Specifications
The PEMs provide 48 VDC power, which is distributed through the filter module to the dial shelf
backplane. The analog isolators in the filter module are provided with 15 VDC. The PEMs suffer no
damage if any or all outputs have no load (no load occurs when there are no cards plugged into the
backplane) or if the maximum input voltage is exceeded; however, input voltages that exceed 75 V
eventually trip the PEM 60 A circuit breaker, and you might have to reset the breaker as needed.
Table A-8 lists DC output voltage and current specifications.
Humidity
Operating
Nonoperating
10 to 90%, noncondensing
10 to 95%, noncondensing
Altitude
Operating
Nonoperating
9,843 ft (3,000 m) at 104° F (40° C)
15,000 ft (4,570 m) over allowable
temperature range
Thermal shock
Operating
Nonoperating
23 to 113° F (5 to 45° C at 0.5° C) per
minute
13 to 158° F (25 to 70° C) with
change-over time between 2 and 3 minutes
Vibration
Operating
Nonoperating
1.12 Grms from 3 to 500 Hz
2 Grms from 3 to 500 Hz
Ripple and noise 200 mV
Battery feed noise 3kHz band between 10KHz and 20 MHz
Voice frequency noise
Radio frequency noise
70 dBrnC
500 mV
RMS
Long-term voltage drift ± 0.5%
Table A-8 Power Entry Module Power Specifications
Power Description
Voltage to backplane
Maximum
Nominal
Minimum
38 VDC
48 VDC
75 VDC
Current
Minimum (SS)
Nominal (SS)
Maximum (SS)
Peak (2 sec)
3 A
42 A
54 A
60 A
Circuit breaker 50A
Table A-7 Dial Shelf Controller Card Environmental Specifications (continued)
Description Specification