Network Card User Manual

Cisco AS5800 Universal Access Server Hardware Installation Guide
System Specifications
A-2
Component Weight (continued)
Dial shelf controller card 8.5 lb each (3.8 kg)
Dial shelf blower assembly 27.5 lb (12.5 kg)
Dial shelf DC power-entry module 8 lb each (3.6 kg)
Dial shelf filter module 5.5 lb (2.5 kg)
AC-input power shelf (empty) 18.5 lb (8.4 kg)
AC-input power supply 14 lb each (6.4 kg)
AC-input power shelf safety cover 3.5 lb (1.6 kg)
Environmental Requirements
Operational temperature
Maximum operating temperature
Acceptable temperature rise
Maximum heat generated
23 to 104°F (5° C to 40° C)
23 to 120°F (5° C to 50° C) (not more than 72 hours)
30°C per hour
8,000 BTU
Backplane 14 slots
Power 44A at 48 VDC
Frequency 50/60 Hz
Heat dissipation 2,000W (6820 Btu/hr)
AC-input voltages and frequency 200 to 240 VAC
50 to 60 Hz
AC voltage and current 200 VAC at 16A maximum
1
wide input with power factor correction
(PFC)
240 VAC at 7A maximum
AC cable 12 American Wire Gauge (AWG), with three leads, an IEC-320
receptacle on the power supply end, and a country-dependent plug on
the power source end
DC-input voltage and current 48 VDC to 60 VDC
DC-input cable 6 AWG for North American environments
10 mm
2
wire for international environments when connecting directly to
a DC power source
DC voltages supplied and maximum,
steady-state current (AC- and DC-input)
48V, 54A maximum
Relative humidity
Operating
Nonoperating
10 to 90%, noncondensing
10 to 95%, noncondensing
Factory-Installed Memory
Dial shelf controller card 32-MB DRAM
T1 or E1 trunk card (dial shelf) 32-MB DRAM
Modem card (dial shelf) 16-MB DRAM
Table A-1 Cisco 5814 Dial Shelf Specifications
Description Specification