User's Manual

3
Release Notes for CPE/CS3 Switch Software Release 2.2.0.3
78-10367-01
Caveats
Finally, the Cisco MGX 8240 CPE can be upgraded from Release 1.1.2.10 directly to Relesae 2.2.0.3
or from Release 2.1.0.6 to Release 2.2.0.3 using the Upgrade Procedure provided in the accompanying
documentation.
Caveats
The following bugs that existed in Release 2.2.0.1 have been fixed and verified in Release 2.2.0.3.
DDTS Number
SeveritySeveSrit
y
Functional
Area
Problem
Description Corrected
Dp31145 2 DS1 DS3 Receive
Yellow Alarm
caused trunk
conditioning
on all DS1s.
Trunk
conditioning is
no longer sent
in this case.
Fixed.
Dp18470 2 BERT Second Circuit
BERT on same
circuit/DS1
fails.
Now
supported.
Fixed.
Dm83980 2 Reference
Clock
Setting force
free run to
same value
causes
inadvertent
clock switch.
Setting to same
value now has
no effect.
Fixed
Dp18436 2 Upgrade Stale
directories and
files cause
upgrade
failures.
Stale
directories
removed; stale
files ignored.
Fixed
Dp18901 2 Alarms Alarm Entity
Id has new
format.
To handle the
Access OC3
and provide a
scheme that
grows for
future releases,
the string
format was
modified.
The format had
to be changed.
Future changes
are not
anticipated.