Quick Start Guide Cisco 2691 Modular Routers INCLUDING LICENSE AND WARRANTY 1 Cisco 90-Day Limited Hardware Warranty Terms 2 Documents, Equipment, and Tools 3 Install Chassis 4 Connect Cables 5 Power Up the Router 6 Perform Initial Configuration 7 Interface Numbering 8 Where to Go Next 9 Obtaining Documentation 10 Documentation Feedback 11 Obtaining Technical Assistance 12 Obtaining Additional Publications and Information
1 Cisco 90-Day Limited Hardware Warranty Terms There are special terms applicable to your hardware warranty and various services that you can use during the warranty period. Your formal Warranty Statement, including the warranties and license agreements applicable to Cisco software, is available on Cisco.com. Follow these steps to access and download the Cisco Information Packet and your warranty and license agreements from Cisco.com. 1. Launch your browser, and go to this URL: http://www.cisco.
2 Documents, Equipment, and Tools User Documentation All the documents referenced in this quick start guide are available online on Cisco.com. To be sure of obtaining the latest information, you should access the online documentation. To view or print a document in its original page format, access the online document, and click the PDF icon. For information about accessing user documentation, see the “Where to Go Next” section on page 23.
Warning Definition IMPORTANT SAFETY INSTRUCTIONS Warning This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. To see translations of the warnings that appear in this publication, refer to the translated safety warnings that accompanied this device.
Avvertenza IMPORTANTI ISTRUZIONI SULLA SICUREZZA Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di intervenire su qualsiasi apparecchiatura, occorre essere al corrente dei pericoli relativi ai circuiti elettrici e conoscere le procedure standard per la prevenzione di incidenti. Per le traduzioni delle avvertenze riportate in questo documento, vedere le avvertenze di sicurezza che accompagnano questo dispositivo.
Aviso INSTRUÇÕES IMPORTANTES DE SEGURANÇA Este símbolo de aviso significa perigo. Você se encontra em uma situação em que há risco de lesões corporais. Antes de trabalhar com qualquer equipamento, esteja ciente dos riscos que envolvem os circuitos elétricos e familiarize-se com as práticas padrão de prevenção de acidentes. Use o número da declaração fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham o dispositivo.
Advarsel VIGTIGE SIKKERHEDSANVISNINGER Dette advarselssymbol betyder fare. Du befinder dig i en situation med risiko for legemesbeskadigelse. Før du begynder arbejde på udstyr, skal du være opmærksom på de involverede risici, der er ved elektriske kredsløb, og du skal sætte dig ind i standardprocedurer til undgåelse af ulykker. Brug erklæringsnummeret efter hver advarsel for at finde oversættelsen i de oversatte advarsler, der fulgte med denne enhed.
Warning This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. Statement 1017 Warning Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces, and watches). Metal objects will heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals.
Warning To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to telephone-network voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports contain TNV circuits. Some LAN and WAN ports both use RJ-45 connectors. Use caution when connecting cables. Statement 1021 Warning This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor.
The brackets for Cisco 2691 routers are shown in Figure 1. The slots in the brackets marked RIGHT are for securing cables with cable ties.
Bracket Installation for Center Mounting with Rear Panel Forward RIGHT RIGHT 82690 Figure 3 NM-HDV SEE MANUAL BEFORE INSTALL ATION SEE MANUAL BEFORE INSTALL ATION DSU 56K SEE MANUAL BEFORE INSTALL ATION Left (narrow) bracket for 19-inch rack Left bracket for 23-inch rack Use two screws on each side.
Installing on Desktop Caution If you place the Cisco router on a desktop, do not place anything that weighs more than 10 pounds (4.5 kilograms) on top of the chassis. Grounding the Chassis You must connect the chassis to a reliable earth ground; the ground wire must be installed in accordance with local electrical safety standards. • For NEBS-compliant grounding, use size AWG 6 (13 mm2) wire and the ground lug provided in the accessory kit.
4 Connect Cables Warning Do not work on the system, or connect or disconnect cables during periods of lightning activity. Statement 1001 System Management Connections The connections described in Table 1 provide system management access.
Caution If you connect dual DC power sources, both sources must be the same polarity. Do not connect a –DC with a +DC source to a Cisco 2691 router. Opposite-polarity sources damage the power supply. DC Wiring Requirements A Cisco 2691 router with a DC-input power supply requires copper wire for the power connections. Table 2 summarizes the wiring requirements. You can connect a single DC power source to either the A input or the B input.
Warning The illustration shows the DC power supply terminal block. Wire the DC power supply as illustrated. The proper wiring sequence is ground to ground, positive to positive, and negative to negative. The ground wire should always be connected first and disconnected last. Statement 239 Warning An exposed wire lead from a DC-input power source can conduct harmful levels of electricity. Be sure that no exposed portion of the DC-input power source wire extends from the terminal block plug.
WAN, LAN, and Voice Connections The connections and cables listed here are described in detail in the following documents: • Cisco 2600 Series Hardware Installation Guide • Cisco Network Modules Hardware Installation Guide • Cisco Interface Cards Installation Guide • Cisco Modular Access Router Cable Specifications To locate these documents, see the “Where to Go Next” section on page 23. Table 3 summarizes some typical WAN, LAN, and voice connections for the Cisco 2691 routers.
5 Power Up the Router Checklist for Power-Up You are ready to power up the Cisco router after the following steps are completed: • Chassis is securely mounted and grounded. • Power and interface cables are connected. • Your PC terminal emulation program is configured for 9600 baud, 8 data bits, 1 stop bit, and no parity. • You have selected passwords for access control. • You have determined the IP addresses for the Ethernet and serial interfaces.
You may see different startup messages: • If you see the following messages, the router has booted with a configuration file and is ready for initial configuration using the Cisco Router and Security Device Manager (SDM): yourname con0 is now available Press RETURN to get started. See the “Initial Configuration Using Cisco Router and Security Device Manager” section on page 19 to learn how to configure your router using SDM or to learn how to obtain SDM and install it on your router.
Initial Configuration Using Cisco Router and Security Device Manager If the following messages appear at the end of the startup sequence, Cisco Router and Security Device Manager (SDM) is installed on your router: yourname con0 is now available Press RETURN to get started. For instructions on configuring your router by using SDM, refer to the Cisco Router and Security Device Manager (SDM) Quick Start Guide.
Step 3 Enter a host name for the router (this example uses 2691): Configuring global parameters: Enter host name [Router]: 2691 Step 4 Enter an enable secret password. This password is encrypted (more secure) and cannot be seen when viewing the configuration: The enable secret is a password used to protect access to privileged EXEC and configuration modes. This password, after entered, becomes encrypted in the configuration.
Step 11 The configuration is displayed: The following configuration command script was created: hostname 2691 enable secret 5 $1$D5P6$PYx41/lQIASK.HcSbfO5q1 enable password xxxxxx line vty 0 4 password xxxxxx snmp-server community public ! no ip routing ! interface FastEthernet0/0 no shutdown media-type 100BaseX half-duplex ip address 172.1.2.3 255.255.0.0 ! interface FastEthernet0/1 shutdown no ip address ! end Step 12 Respond to the following prompts. Select [2] to save the initial configuration.
For interface numbering information, see the “Interface Numbering” section on page 22. Step 1 To proceed with manual configuration using the CLI, enter no. Would you like to enter the initial configuration dialog? [yes/no]: no Step 2 Press Return to terminate autoinstall and continue with manual configuration. Would you like to terminate autoinstall? [yes] Return Several messages are displayed, ending with a line similar to the following: ... Copyright (c) 1986-2000 by cisco Systems, Inc.
• A WIC in each WIC slot (containing interfaces Serial 0/0 and Serial 0/1 in physical slot W0, interface Serial 0/2 in physical slot W1, and interface BRI 0/0 in physical slot W2) – If physical slot W0 is empty and physical slot W1 contains a 1-port serial WIC, the interface number in the WIC is numbered Serial 0/0.
To access documentation on Cisco.com: For Cisco 2600 series platform documentation, start on Cisco.com at http://www.cisco.com, and select Products & Services > Routers > Cisco 2600 Series Multiservice Platforms > Technical Documentation > Document type > Document. For Cisco IOS software documentation, start on Cisco.com at http://www.cisco.com, and select Products & Services > IOS Software > Cisco IOS Software Releases > Your Cisco IOS software release.
10 Documentation Feedback You can send comments about technical documentation to bug-doc@cisco.com. You can submit comments by using the response card (if present) behind the front cover of your document or by writing to the following address: Cisco Systems Attn: Customer Document Ordering 170 West Tasman Drive San Jose, CA 95134-9883 We appreciate your comments.
Definitions of Service Request Severity To ensure that all service requests are reported in a standard format, Cisco has established severity definitions. Severity 1 (S1)—Your network is “down,” or there is a critical impact to your business operations. You and Cisco will commit all necessary resources around the clock to resolve the situation.
Corporate Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 526-4100 European Headquarters Cisco Systems International BV Haarlerbergpark Haarlerbergweg 13-19 1101 CH Amsterdam The Netherlands www-europe.cisco.com Tel: 31 0 20 357 1000 Fax: 31 0 20 357 1100 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA www.cisco.