Owner's manual

Table Of Contents
DS785UM1 21-23
Copyright 2007 Cirrus Logic
I
2
S Controller
EP93xx User’s Guide
2
1
2
1
RXDIR: Receive data shift direction.
0 - MSB first
1 - LSB first
I2SRXCtrl
Address:
0x8082_005C - Read/Write
Default:
0x0000_0000
Definition:
Control Register
Bit Descriptions:
RSVD: Reserved. Unknown During Read. Must be written as “0”.
ROFLIE: Receive interrupt enable.
Active high
RXFull_int_level: Rx full interrupt level select.
0 - Generate interrupt when FIFO is half full.
1 - Generate interrupt when FIFO is full.
I2SRXWrdLen
Address:
0x8082_0060 - Read/Write
Default:
0x0000_0000
Definition:
Word Length
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
RSVD
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
RSVD ROFLIE RXFull_int_level
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
RSVD
1514131211109876543210
RSVD WL