Owner's manual

Table Of Contents
21-22 DS785UM1
Copyright 2007 Cirrus Logic
I
2
S Controller
EP93xx User’s Guide
2
1
2
1
21
I2SRX2Rt
Address:
0x8082_0054 - Read Only
Default:
0x0000_0000
Definition:
Receive right data word for channel 2.
Bit Descriptions:
i2s_rx2_right: Receive right data word for channel 2.
I2SRXLinCtrlData
Address:
0x8082_0058 - Read/Write
Default:
0x0000_0000
Definition:
Receive Line Control Data Register
Bit Descriptions:
RSVD: Reserved. Unknown During Read. Must be written as “0”.
Left_Right_Justify: Receiver Data word Justification when being received on
the SDI line input.
0 - Left justification.
1 - Right justification.
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
i2s_rx2_right
1514131211109876543210
i2s_rx2_right
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
RSVD
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
RSVD Left_Right_Justify RXDIR