Owner's manual

Table Of Contents
20-6 DS785UM1
Copyright 2007 Cirrus Logic
Real Time Clock With Software Trim
EP93xx User’s Guide
2
0
2
0
20
RTCLoad
Address:
0x8092_000C - Read/Write
Default:
0x0000_0000
Definition:
RTC Load Register. Contains the 32 bit load value. Data written to this register
is transferred to the RTCData on the next 1 Hz tick.
Bit Descriptions:
RTCLR: Load value.
RTCCtrl
Address:
0x8092_0010 - Read/Write
Default:
0x0000_0000
Definition:
RTC Interrupt Control Register. Contains the interrupt enable control bit.
Bit Descriptions:
RSVD: Reserved, unknown during read.
MIE: Match Interrupt Enable,
1 - RTC match interrupt is enabled
0 - interrupt disabled.
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
RTCLR
1514131211109876543210
RTCLR
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
RSVD
1514131211109876543210
RSVD MIE