Owner's manual

Table Of Contents
14-32 DS785UM1
Copyright 2007 Cirrus Logic
UART1 With HDLC and Modem Control Signals
EP93xx User’s Guide
1
4
1
4
14
Definition:
HDLC Receive Information Buffer Register. This register is loaded when the
last data byte in a received frame is read from the receive FIFO. The CPU has
until the end of the next frame to read this register, or the RIL bit in the HDLC
Status Register is set.
Bit Descriptions:
RSVD: Reserved. Unknown During Read.
BPLLE: Buffered Digital PLL Error.
1 - Receiver aborted last frame because DPLL lost the
carrier.
0 - Receiver did not abort because DPLL lost the carrier.
This bit is only valid when receiving Manchester-encoded
synchronous HDLC.
BC: Received frame Byte Count.
The total number of valid bytes read from the RX FIFO
during the last HDLC frame.
BFRE: Buffered Framing Error.
0 - No framing errors were encountered in the last frame.
1 - A framing error occurred during the last frame, causing
the remainder of the frame to be discarded.
BROR: Buffered Receiver Over Run.
0 - The RX buffer did not overrun during the last frame.
1 - The receive FIFO did overrun during the last frame.
The remainder of the frame was discarded.
BCRE: Buffered CRC Error.
0 - No CRC check errors occurred in the last frame.
1 - The CRC calculated on the incoming data did not
match the CRC value contained in the last frame.
BRAB: Buffered Receiver Abort.
0 - No abort occurred in the last frame.
1 - The last frame was aborted.
UART1HDLCSts
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
RSVD PLLE PLLCC
1514131211109876543210
LNKIDL CRE ROR TBY RIF RSVD RAB RTO EOF RFL RIL RFC RFS TAB TFC TFS