UART1 With HDLC and Modem Control Signals
EP93xx User’s Guide
1
4
1
4
14
UART1Ctrl
Address:
0x808C_0014 - Read/Write
Default:
0x0000_0000
Definition:
UART1 Control Register
Bit Descriptions:
RSVD: Reserved. Unknown During Read.
LBE: Loopback Enable. If this bit is set to 1, data sent to TXD is
received on RXD. This bit is cleared to 0 on reset, which
disables the loopback mode.
RTIE: Receive Timeout Enable. If this bit is set to 1, the receive
timeout interrupt is enabled.
TIE: Transmit Interrupt Enable. If this bit is set to 1, the transmit
interrupt is enabled.
RIE: Receive Interrupt Enable. If this bit is set to 1, the receive
interrupt is enabled.
MSIE: Modem Status Interrupt Enable. If this bit is set to 1, the
modem status interrupt is enabled.
UARTE: UART Enable. If this bit is set to 1, the UART is enabled.
Data transmission and reception occurs for UART signals.
UART1Flag
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
RSVD
1514131211109876543210
RSVD LBE RTIE TIE RIE MSIE RSVD UARTE
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
RSVD
1514131211109876543210
RSVD TXFE RXFF TXFF RXFE BUSY DCD DSR CTS