Owner's manual

Table Of Contents
7-80 DS785UM1
Copyright 2007 Cirrus Logic
Raster Engine With Analog/LCD Integrated Timing and Interface
EP93xx User’s Guide
7
7
7
Bit Descriptions:
RSVD: Reserved - Unknown during read
STOP: Stop - Read/Write
The STOP value is the value of the Vertical down counter
at which the VSIGEN signal becomes inactive (stops).This
indicates the end of the signature calculation for the
Vertical frame. VSIGEN is an internal block signal. The
SIG_ENABLE control to the video signature analyzer is
enabled by the logical AND of VSIGEN and HSIGEN.
STRT: Start - Read/Write
The STRT value is the value of the Vertical down counter
at which the VSIGEN signal becomes active (starts).This
indicates the start of the signature calculation for the
Vertical frame. VSIGEN is an internal block signal. The
SIG_ENABLE control to the video signature analyzer is
enabled by the logical AND of VSIGEN and HSIGEN.
HSigStrtStop
Address: 0x8003_020C
Default: 0x0000_0000
Definition: Horizontal Signature Bounds Start/Stop register
Bit Descriptions:
RSVD: Reserved - Unknown during read
STOP: Stop - Read/Write
The STOP value is the value of the horizontal down
counter at which the HSIGEN signal becomes inactive
(stops). This indicates the end of the signature calculation
for a horizontal line. HSIGEN is an internal block signal.
The SIG_ENABLE control to the video signature analyzer
is enabled by the logical AND of VSIGEN and HSIGEN.
STRT: Start - Read/Write
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
RSVD STOP
1514131211109876543210
RSVD STRT