Owner manual

18 DS580F6
CS8406
7. CONTROL PORT REGISTER SUMMARY
Note: Reserved registers must not be written to during normal operation. Some reserved registers are used for
test modes, which can completely alter the normal operation of the CS8406.
Addr
(HEX)
Function 7 6 5 4 3 2 1 0
00 Reserved 0 0 0 0 0 0 0 0
01 Control 1 0 VSET 0 MUTEAES 0 INT1 INT0 TCBLD
02 Control 2 0 0 0 0 0 MMT MMCST MMTLR
03 Data Flow Control 0 TXOFF AESBP 0 0 0 0 0
04 Clock Source Control 0 RUN CLK1 CLK0 0 0 0 0
05 Serial Input Format SIMS SISF SIRES1 SIRES0 SIJUST SIDEL SISPOL SILRPOL
06 Reserved 0 0 0 0 0 0 0 0
07 Interrupt 1 Status TSLIP 0 0 0 0 0 EFTC 0
08 Interrupt 2 Status 0 0 0 0 0 EFTU 0 0
09 Interrupt 1 Mask TSLIPM 0 0 0 0 0 EFTCM 0
0A Interrupt 1 Mode (MSB) TSLIP1 0 0 0 0 0 EFTC1 0
0B Interrupt 1 Mode (LSB) TSLIP0 0 0 0 0 0 EFTC0 0
0C Interrupt 2 Mask 0 0 0 0 0 EFTUM 0 0
0D Interrupt 2 Mode (MSB) 0 0 0 0 0 EFTU1 0 0
0E Interrupt 2 Mode (LSB) 0 0 0 0 0 EFTU0 0 0
0F-11 Reserved 0 0 0 0 0 0 0 0
12 CS Data Buffer Control 0 0 BSEL 0 0 EFTCI CAM 0
13 U Data Buffer Control 0 0 0 UD UBM1 UBM0 0 EFTUI
1D-1F Reserved 0 0 0 0 0 0 0 0
20-37 C or U Data Buffer
7F ID and Version ID3 ID2 ID1 ID0 VER3 VER2 VER1 VER0
Table 1. Control Register Map Summary