Owner manual

CS5566
DS806PP2 23
5/4/09
3.10 Digital Filter Characteristics
The digital filter is designed for fast settling, therefore it exhibits very little in-band attenuation. The filter
attenuation is -0.0414 dB at 2.5 kHz when sampling at 5 kSps.
Figure 20. Digital Filter Response (DC to 2.5 kHz)
Frequency (Hz)
-0.001646 dB
-0.00663 dB
-0.0149 dB
-0.0262 dB
-0.0414 dB
fs = 5 kSps