Manual
CS5464
34 DS682F3
8.3.5 Mode Control (Modes) – Address: 16
Default = 0
Ichan Chooses an energy channel to drive the
E
PULSE
, S
PULSE
, and Q
PULSE
registers.
0 = Pulse registers driven by energy channel 1.
1 = Pulse registers driven by energy channel 2.
VFIX Use internal RMS voltage reference instead of voltage input for average active power.
0 = Use voltage input.
1 = Use Internal RMS voltage reference,
VF
RMS
.
IvsE Use I
RMS
results instead of P
AVG
for energy channel selection
0 = Use
P1
AVG
and P2
AVG
instead of I1
RMS
and I2
RMS
.
1 = Use I1
RMS
and I2
RMS
instead of P1
AVG
and P2
AVG
.
E1MODE[1:0] E1, E2, and E3 alternate Output Mode (when enabled by E2MODE)
00 = E1
, E2 = P1
AVG
, P2
AVG
01 = E1, E2 = S1, S2
10 = E1, E2 = Q1
AVG
, Q2
AVG
11 = E1, E2 = Q1
WB
, Q2
WB
Ihold Suspends automatic channel selection.
0 = Channel selected automatically by magnitude compare.
1 = Channel selected by application (host).
E2MODE[1:0] E2
Output Mode
00 = Energy Sign
01 = Apparent Energy
10 = Channel In Use
11 = Enable E1MODE
VHPF2:IHPF2 High-pass Filter Enable for Energy Channel 2
00 = No Filter
01 = HPF on Current, PMF on Voltage
10 = HPF on Voltage, PMF on Current
11 = HPF on both Voltage and Current
VHPF1:IHPF1 High-pass Filter Enable for Energy Channel1
00 = No Filter
01 = HPF on Current, PMF on Voltage
10 = HPF on Voltage, PMF on Current
11 = HPF on both Voltage and Current
E3MODE[1:0] E3
Output Mode (with E1MODE disabled)
00 = Reactive Energy (default)
01 = Power Fail Monitor
10 = Voltage Sign
11 = Apparent Energy
23 22 21 20 19 18 17 16
IchanVFIX------
15 14 13 12 11 10 9 8
IvsE E1MODE1 E1MODE0 Ihold - E2MODE1 E2MODE0 VHPF2
76543210
IHPF2 VHPF1 IHPF1 - E3MODE1 E3MODE0 POS AFC