User guide
DS563F2 5
CS5381
2. CHARACTERISTICS AND SPECIFICATIONS
All Min/Max characteristics and specifications are guaranteed over the Specified Operating Conditions. Typical per-
formance characteristics and specifications are derived from measurements taken at VA = 5.0 V, VD = VL = 3.3 V,
and TA = 25
°C.
SPECIFIED OPERATING CONDITIONS
(GND = 0 V; all voltages with respect to 0 V.)
ABSOLUTE MAXIMUM RATINGS
(GND = 0 V, All voltages with respect to ground.) (Note 1)
Notes:
1. Operation beyond these limits may result in permanent damage to the device. Normal operation is not
guaranteed at these extremes.
2. Any pin except supplies. Transient currents of up to ±100 mA on the analog input pins will not cause
SRC latch-up.
3. The maximum over/under voltage is limited by the input current.
Parameters Symbol Min Typ Max Units
DC Power Supply
DC Power Supplies: Positive Analog
Positive Digital
Positive Logic
VA
VD
VL
4.75
3.1
2.37
5.0
-
-
5.25
5.25
5.25
V
V
V
Ambient Operating Temperature (Power Applied)
T
A
-10 - +70 °C
Parameter Symbol Min Typ Max Units
DC Power Supplies: Analog
Logic
Digital
VA
VL
VD
-0.3
-0.3
-0.3
-
-
-
+6.0
+6.0
+6.0
V
V
V
Input Current (Note 2)
I
in
-10 - +10 mA
Analog Input Voltage (Note 3)
V
IN
GND-0.7 - VA+0.7 V
Digital Input Voltage (Note 3)
V
IND
-0.7 - VL+0.7 V
Ambient Operating Temperature (Power Applied)
T
A
-50 - +95 °C
Storage Temperature
T
stg
-65 - +150 °C