DAC AC DIFFERENTIAL MODES 1, 2, 3
Notes: 22. Maximum amplitude for DAC operation above 100 Hz. A reduced amplitude for higher frequencies is
required to guarantee stability of the low-power ΔΣ DAC architecture.
23. Full-scale accuracy tests the matching of 1/1 attenuation across multiple devices.
24. Relative accuracy tests the tracking of 1/1,1/2,1/4,1/16,1/32,1/64 attenuation relative to 1/8 attenuation
on a single device.
Parameter Symbol Min Typ Max Unit
AC Differential Characteristics
Full-scale Differential AC Output 1/1
1/2
1/4
1/8
1/16
1/32
1/64
VAC
FS
-
-
-
-
-
-
-
5
2.5
1.25
625
312.5
156.25
78.125
-
-
-
-
-
-
-
V
pp
V
pp
V
pp
mV
pp
mV
pp
mV
pp
mV
pp
Full-scale Bandwidth (Note 10) VAC
BW
--100Hz
Impulse Amplitude (Note 10, 22)VAC
IMP
---20dBfs
AC Differential Accuracy
Full-scale Accuracy (Note 3, 23)VAC
ABS
-+1+2%FS
Relative Accuracy (Note 24)VAC
REL
-+1+2%FS
Full-scale Drift (Note 19)VAC
TC
-8-μV/°C
DC Common Mode Characteristics
Common Mode (Note 15) VAC
CM
- (VA-)+2.35 -V
Common Mode Drift (Note 15, 19)VAC
CMTC
-2-μV/°C