3.0 REGISTER DESCRIPTION
3.1 DIFFERENTIAL DC OFFSET CALIBRATION
Mode Control Register (address 01h)
Access:
R/W in I
2
C and SPI.
Default:
0 - Disabled
Function:
Enabling this function will initiate a calibration to minimize the differential DC offset. This function will be
automatically reset following completion of the calibration sequence.
3.2 SOFT MUTE
Mode Control Register (address 01h)
Access:
R/W in I
2
C and SPI.
Default:
0 - Enabled
Function:
The analog outputs will ramp to a muted state when enabled. The ramp requires 1152 left/right clock cy-
cles in Single Speed, 2304 cycles in Double Speed and 4608 cycles in Quad Speed mode. The bias volt-
age on the outputs will be retained and MUTEC
will go low at the completion of the ramp period.
The analog outputs will ramp to a normal state when this function transitions from the enabled to disabled
state. The ramp requires 1152 left/right clock cycles in Single Speed, 2304 cycles in Double Speed and
4608 cycles in Quad Speed mode. The MUTEC
will go high immediately on disabling of MUTE.
76543210
CAL MUTE
M4 M3 M2 M1 M0 PDN
CAL MODE
0 Disabled : CAL complete
1 Enabled : CAL initiated
Table 1.
76543210
CAL
MUTE
M4 M3 M2 M1 M0 PDN
MUTE
MODE
0 Enabled
1 Disabled
Table 2.