Owner's manual
CS4391A
DS600PP3 17
3.5 MODE CONTROL 2 (ADDRESS 05H)
INVERT_A (Invert Channel A)
Default = ‘0’.
0 - Disabled
1 - Enabled
INVERT_B (Invert Channel B)
Default = ‘0’.
0 - Disabled
1 - Enabled
CPEN (Control Port Enable)
Default = ‘0’
0 - Disabled (Stand-Alone Mode)
1 - Enabled (Control Port Mode)
PDN (Power-Down)
Default =’1’.
0 - Disabled
1 - Enabled
MUTEC A=B
Default = ‘0’.
0 - Disabled
1 - Enabled
FREEZE
Default = 0.
0 - Disabled
1 - Enabled
MCLK Divide
Default = 0.
0 - Disabled
1 - Enabled
76543210
INVERT_A INVERT_B CPEN PDN MUTEC A = B FREEZE MCLK Divide Reserved
00110000