6.3.6 Mute Pin Control (MUTEC1, MUTEC0)
Default = 00
00 - Six mute control signals
01, 10 - One mute control signal
11 - Three mute control signals
Function:
Selects how the internal mute control signals are routed to the MUTEC1 through MUTEC6 pins. When
set to ‘00’, there is one mute control signal for each channel: AOUT1A on MUTEC1, AOUT1B on
MUTEC2, etc. Wh en set to ‘01’ or ‘10’, th ere is a single mute contr ol sign al on th e MUTEC1 p in. When
set to ‘11’, there are three mute control signals, one for each stereo pair: AOUT1A and AOUT1B on
MUTEC1, AOUT2A and AOUT2B on MUTEC2, and AOUT3A and AOUT3B on MUTEC3.
6.4 Filter Control (Address 04h)
6.4.1 Interpolation Filter Select (FILT_SEL)
Default = 0
0 - Fast roll-off
1 - Slow roll-off
Function:
This function allows the user to select whether the interpol ation filter has a fast or slow roll off . For filter
characteristics, please see Section 2.
6.4.2 De-Emphasis Control (DEM)
Default = 00
00 - Disabled
01 - 44.1 kHz
10 - 48 kHz
11 - 32 kHz
Function:
Selects the appropriate digital filter to maintain the standard 15
µs/50 µs digital de-emphasis filter re-
sponse at 32, 44.1 or 48 kHz sample rates. (see Figure 13)
De-emphasis is only available in Sing le-Speed Mode.
6.4.3 Soft Ramp-Down Before Filter Mode Change (RMP_DN)
Default = 0
0 - Disabled
1 - Enabled
Function:
If either the FILT_SEL or DEM bits are changed, the DAC will stop conversion for a period of time to
change filter values. This bit selects how the data is effected prior to an d after the change of the filter val-
76543210
Reserved Reserved Reserved FILT_SEL Reserved DEM1 DEM0 RMP_DN
00000000