Owner's manual

16 DS782F2
CS4349
2.9 Digital Characteristics
2.10 Power and Thermal Characteristics
Notes: 13. Current consumption increases with increasing Fs within the range of a speed mode. Variance between
speed modes is small. Typ and Max values are based on Fs = 48 kHz.
14. I
LC
measured with no external loading on pin 2 (SDA).
15. Power-down mode is defined as RST
pin = Low with all clock and data lines held static.
16. Valid with the recommended capacitor values on VFILT, VQ, and VBIAS+ as shown in the typical con-
nection diagram in Figure 10.
Table 10. Digital Characteristics
Parameters Symbol Min Typ Max Units
High-Level Input Voltage VLC or VLS = 5.0 V V
IH
0.7•V
L
-- V
VLC or VLS = 3.3 V
V
IH
2.0 - - V
VLS = 2.5 V
V
IH
1.7 - - V
VLS = 1.5 V
V
IH
0.75•V
L
-- V
High-Level Input Voltage VLC or VLS = 5.0 V V
IL
--0.35V
L
V
VLC or VLS = 3.3 V
V
IL
--0.8V
VLS = 2.5 V
V
IL
--0.7V
VLS = 1.5 V
V
IL
--0.25V
L
V
Input Leakage Current I
in
--±10A
Input Capacitance - 8 - pF
Maximum MUTEC Drive Current - 2 - mA
MUTEC High-Level Output Voltage V
OH
-VA- V
MUTEC Low-Level Output Voltage V
OL
-0- V
Table 11. Power and Thermal Characteristics
Parameters Symbol Min Typ Max Units
Power Supply Current - Normal Operation (Note 13) VA= 5.0 V I
A
-2834mA
VA= 3.3 V I
A
-2429mA
VLS
= VLC
=5.0 V (Note 14) I
LS
-46mA
VLS
= VLC
=3.3 V (Note 14) I
LS
-25mA
VLS
= VLC
= 5.0 V (Note 14) I
LC
-1418mA
VLS
= VLC
= 3.3 V (Note 14) I
LC
-1418mA
Power Supply Current - Power-Down State (Note 15)
VA, VLS
,
VLC I
pd
-100- A
Power Dissipation - Normal Operation (Note 13)
VA = VLC= VLS = 5.0 V - 230 290 mW
VA = VLC= VLS = 3.3 V - 132 171 mW
Power Dissipation - Power-Down State (Note 15)
VA = VLC= VLS = 5.0 V - 0.5 - mW
VA = VLC= VLS = 3.3 V - 0.33 - mW
Power Supply Rejection Ratio (Note 16) (1 kHz) PSRR - 60 - dB