User guide

CS4341
30 DS298F5
6.5.2 VOLUME (VOLx) BIT 0-6
Default = 0 dB (No Attenuation)
Function:
The digital volume control allows the user to attenuate the signal in 1 dB increments from 0 to -90 dB.
Volume settings are decoded as shown in Table 7. The volume changes are implemented as dictated
by the Soft and Zero Cross bits in the Transition and Mixing Control (address 02h) register. All volume
settings less than - 94 dB are equivalent to enabling the Mute bit.
Binary Code Decimal Value Volume Setting
0000000 0 0 dB
0010100 20 -20 dB
0101000 40 -40 dB
0111100 60 -60 dB
1011010 90 -90 dB
Table 7. Example Digital Volume Settings