Manual

CS43122
16
MCLK
10
Master Clock (
Input
) - The master clock frequency must be either 256x, 384x,
512x or 768x the input sample rate in Operational Mode 0; either 128x, 192x 256x
or 384x the input sample rate in Operational Mode 1 ; or 64x, 96x 128x or 192x the
input sample rate in Operational Mode 2 . Tables 4-6 illustrate the standard audio
sample rates and the required master clock frequencies.
SCLK
11
Serial Clock
(Input) -
Clocks individual bits of serial data into the SDATA pin. The
required relationship between the Left/Right clock, serial clock and serial data is
defined by either the Mode Control Byte in Control Port Mode or the M0 - M4 pins
in Hardware Mode. The options are detailed in Figures 20-23.
LRCK
12
Left/Right Clock
(Input) -
The Left/Right clock determines which channel is cur-
rently being input on the serial audio data input, SDATA. The frequency of the
Left/Right clock must be at the input sample rate. Audio samples in Left/Right
sample pairs will be simultaneously output from the digital-to-analog converter
whereas Right/Left pairs will exhibit a one sample period difference. The required
relationship between the Left/Right clock, serial clock and serial data is defined by
the Mode Control Byte and the options are detailed in Figures 20-23.
SDATA
13
Serial Audio Data
(Input) -
Two’s complement MSB-first serial data is input on
this pin. The data is clocked into SDATA via the serial clock and the channel is
determined by the Left/Right clock. The required relationship between the
Left/Right clock, serial clock and serial data is defined by the Mode Control Byte
and the options are detailed inin Figures 20-23.
Sample Rate
(kHz)
MCLK (MHz)
256x 384x 512x 768x
32 8.1920 12.2880 16.3840 24.5760
44.1 11.2896 16.9344 22.5792 33.8688
48 12.2880 18.4320 24.5760 36.8640
Table 1. Operational Mode 0 (16 to 55 kHz sample rates) Common Clock
Frequencies
Sample Rate
(kHz)
MCLK (MHz)
128x 192x 256x 384x
48 6.1440 8.1920 12.2880 16.3840
64 8.1920 12.2880 16.3840 24.5760
88.2 11.2896 16.9344 22.5792 33.8688
96 12.2880 18.4320 24.5760 36.8640
Table 2. Operational Mode 1 (45 to 105 kHz sample rates) Common Clock
Frequencies
Sample Rate
(kHz)
MCLK (MHz)
64x 96x 128x 192x
176.4 11.2896 16.9344 22.5792 33.8688
192 12.2880 18.4320 24.5760 36.8640
Table 3. Operational Mode 2 (95 to 200 kHz sample rates) Common Clock
Frequencies