Instruction Manual
DS773F1 13
CS42L55
ADC DIGITAL FILTER CHARACTERISTICS
Notes:
8. Response is clock-dependent and will scale with Fs. Note that the response plots (Figures 27 to 30 on
page 70) have been normalized to Fs and can be de-normalized by multiplying the X-axis scale by Fs.
HPF parameters are for Fs = 48 kHz.
9. Characteristics are based on the default setting in register “HPF Control (Address 09h)” on page 47.
10. Settling time decreases at higher corner frequency settings.
Parameter (Note 8) Min Typ Max Unit
Frequency Response (20 Hz to 20 kHz)
-0.07 - +0.02 dB
Passband to -0.05 dB corner
to -3 dB corner
-
-
0.421
0.495
-
-
Fs
Fs
Stopband
0.52 - - Fs
Stopband Attenuation
33 - - dB
Total Group Delay
- 7.6/Fs - s
High-Pass Filter Characteristics (48 kHz Fs) (Note 9)
Passband to -3.0 dB corner
to -0.05 dB corner
-
-
1.87
17.15
-
-
Hz
Hz
Passband Ripple
- - 0.15 dB
Phase Deviation @ 20 Hz
-5.3-Deg
Filter Settling Time (Note 10)
-
10
5
/Fs
-s