Owner manual
DS963F4 39
CS35L32
7.13 ADSP Control
7.13 ADSP Control
Address 0x0F
R/W
76543210
ADSP_DRIVE M/S DATCNF[1:0] SHARE —
Default00100000
Bits Name Description
7ADSP_
DRIVE
ADSP output drive strength. Selects the drive strength used for the ADSP outputs. These outputs include SDOUT as well as
SCLK and LRCK when the device is in Master Mode. Table 3-8 lists drive-strength specifications.
0 (Default) 1x
10.5x
6 M/S ADSP Master/Slave Mode. Configures the ADSP I/O clocking. See Section 4.11.2 for details.
0 (Default) Slave (SCLK/LRCK input only)
1 Master (SCLK/LRCK output only)
5:4 DATCNF Data configuration for dual CS35L32 applications only. Determines the data packed in a two-CS35L32 configuration.
00 Left/right channels VMON[11:0], IMON[11:0], VPMON[7:0]. See Table 4-10.
01 Left/right channels VMON[11:0], IMON[11:0], STATUS. See Table 4-11.
10 (Default) left/right channels VMON[15:0], IMON [15:0]. See Table 4-12.
11 Left/right channels VPMON[7:0], STATUS. See Table 4-13.
3 SHARE SDOUT sharing. Determines whether one or two CS35L32 devices are on board sharing SDOUT.
0 (Default) One IC. Data configuration per Table 4-9.
1 Two ICs. For data configuration, refer to DATCNF (bits 5:4. above).
2:0 — Reserved
7.14 Class D Amplifier Control
Address 0x10
R/W
76543210
— AMP_GAIN[2:0] GAIN_CHG_ZC —
Default00010100
Bits Name Description
7:6 — Reserved
5:3 AMP_GAIN Amplifier gain. Configures the amplifier gain. Step size: ~3 dB
000 Mute (–80 dB)
001 9 dB
010 (Default) 12 dB
011 15 dB
100 18 dB
101–111 Reserved
2GAIN_
CHG_ZC
Gain change zero-cross. Configures when AMP_GAIN (see p. 39) changes are applied.
0 Changes are not aligned to zero crosses.
1
(Default) Changes are delayed to occur at zero crossings
1:0 — Reserved
7.15 Protection Release Control
Address 0x11
R/W
7654 3 2 10
— AMP_SHORT_RLS — OTE_RLS
Default 0 0 0 0 0 0 0 0
Bits Name Description
7:3 — Reserved
2AMP_
SHORT_
RLS
Amplifier short protection release. Releases amplifier short protection that places the device into Speaker-Safe Mode if the
amplifier short condition is no longer present, which can be determined by reading AMP_SHORT (see Section 7.19) twice.
0 (Default)
1
0 1 0 sequence
If the amplifier short condition is present, Speaker-Safe Mode is applied.
After the sequence, if the short condition is no longer present, Speaker-Safe Mode is cleared unless
an OTE condition is active. During the sequence, short monitoring is inactive because the amplifier is
in an OFF state, as explained in Section 7.19. Short monitoring resumes after the sequence.
1—Reserved