3 Characteristics and Specifications
Table 3-12. Switching Specifications: ADSP in I
2
S Mode
Test conditions, except where noted otherwise: VA = 1.8 V, VP = 3.6 V, VBST = 5.0 V, T
A
= +25°C, Inputs: Logic 0 = GNDA = GNDP = 0 V, Logic 1 =
VA; C
LOAD
= 30 pF. Section 9 describes some parameters in detail; input timings are measured at V
IL
and V
IH
thresholds; output timings are measured
at V
OL
and V
OH
thresholds (see Table 3-8).
Parameters Symbol
1
1.ADSP timing in I
2
S Mode
Min Max Units
Slave Mode Input sample rate (LRCK)
2
2.Clock rates should be stable when the CS35L32 is powered up.
Fs 49 kHz
LRCK duty cycle 45 55 %
SCLK frequency 1/t
Ps
64•Fs Hz
SCLK duty cycle 45 55 %
LRCK setup time before SCLK rising edge t
SS(LK–SK)
40 ns
LRCK hold time after SCLK rising edge t
HS(SK–LK)
20 ns
SDOUT time from SCLK to data valid start
3
3.Minimum data valid window, as shown in signal diagram, is (SCLKperiod – 300 + 155) ns. For SCLK = 64*Fs =64*48 = 3072 kHz, this is 180 ns.
t
DataValidStrt
300 ns
SDOUT time from SCLK to data valid end
3
t
DataValidEnd
155 ns
Master Mode OUTPUT sample rate (LRCK)
4
4.In Master Mode, the output sample rate follows MCLK rate divided down per Table 4-14 and Section 7.7. Any deviation in internal MCLK from the
nominal supported rates is directly imparted to the output sample rate by the same factor (e.g., +100-ppm offset in the frequency of MCLK becomes
a +100-ppm offset in LRCK).
Fs
[4]
kHz
LRCK duty cycle 45 55 %
SCLK frequency 1/t
PM
64•Fs Hz
SCLK duty cycle RATIO = 0
RATIO = 1
[5]
5.If RATIO = 1, the MCLK(INT)-to-LRCK ratio is 125. The device periodically extends SCLK high time to compensate for a fractional MCLK/SCLK ratio
45
33
55
67
%
%
LRCK setup time before SCLK rising edge t
SM(LK–SK)
35 ns
LRCK hold time after SCLK rising edge t
HM(SK–LK)
20 ns
SDOUT time from SCLK to data valid start
3
t
DataValidStrt
300 ns
SDOUT time from SCLK to data valid end
3
t
DataValidEnd
155 ns
//
LRCK
SCLK
SDOUT
T
P
Note:
= “S” or “M”
t
S(LK-SK)
t
H(SK-LK)
t
DataValidStrt
t
DataValidEnd
DataValidWind