Instruction Manual

CS35L01/03
8 DS909F1
4. CHARACTERISTICS & SPECIFICATIONS
Test Conditions (unless otherwise specified): GND = 0 V; All voltages with respect to ground; Input signal = 997 Hz
differential sine wave; T
A
= 25°C; VBATT = 5.0 V; R
L
=8; 22 Hz to 20 kHz measurement bandwidth; Measure-
ments taken with AES17 measurement filter and Audio Precision AUX-0025 passive filter.
RECOMMENDED OPERATING CONDITIONS
GND = 0 V; All voltages with respect to ground. Please see (Note 4).
ABSOLUTE MAXIMUM RATINGS
GND = 0 V; All voltages with respect to ground.
WARNING: Operation at or beyond these limits may result in permanent damage to the device.
Notes:
4. Functionality is not guaranteed or implied outside of these limits. Operation outside of these limits may
adversely affect device reliability.
5. No external loads should be connected to the LFILT+ net. Any connection of a load to this point may
result in errant operation or performance degradation in the device.
Parameters Symbol Min Typ Max Units
DC Power Supply
Supply Voltage VBATT 2.5 5.0 5.5 V
Temperature
Ambient Temperature T
A
-10 - +70 °C
Junction Temperature T
J
-10 - +150 °C
Parameters Symbol Min Max Units
DC Power Supply
Supply Voltage VBATT -0.3 6.0 V
LFILT+ Current (Note 5) I
VDREG
-10A
Inputs
Input Current I
in
10mA
Temperature
Ambient Operating Temperature (power applied) T
A
-20 +125 °C
Storage Temperature T
stg
-65 +150 °C