Instruction Manual
CS2200-OTP
DS842F2 23
10.ORDERING INFORMATION
The CS2200-OTP is ordered as an un-programmed device. The CS2200-OTP can also be factory programmed for
large quantity orders. Please see “Programming Information” on page 21 for more details.
11.REVISION HISTORY
Product Description Package
Pb-Free Grade
Temp Range Container
Order#
CS2200-OTP Clocking Device 10L-MSOP Yes
Commercial
-10° to +70°C Rail CS2200P-CZZ
CS2200-OTP Clocking Device 10L-MSOP Yes -10° to +70°C
Tape and
Reel
CS2200P-CZZR
CS2200-OTP Clocking Device 10L-MSOP Yes
Automotive
-40° to +85°C Rail CS2200P-DZZ
CS2200-OTP Clocking Device 10L-MSOP Yes -40° to +85°C
Tape and
Reel
CS2200P-DZZR
CDK2000 Evaluation Platform - Yes - - - CDK2000-CLK
Release Changes
F1 Updated Period Jitter specification in “AC Electrical Characteristics” on page 7.
Updated Crystal and Ref Clock Frequency specifications in “AC Electrical Characteristics” on page 7.
Added Mode pin toggle requirement to startup for CDK programmed devices to “Required Power Up
Sequencing for Programmed Devices” on page 16.
F2 Updated to add Automotive Grade temperature ranges and ordering options.