Owner's manual

28 ©Copyright 2005 Cirrus Logic, Inc. DS651UM23
Version 2.3
CobraNet Hardware User’s Manual
Host Management Interface (HMI)
7.4 Protocol and Messages
The message conduit is used to issue commands to the CS1810xx/CS4961xx and
retrieve HMI status. The data conduit is used to transfer data dependent on the HMI state
as determined by commands issued by the host via the message conduit.
7.4.1 Messages
Messages are used to efficiently invoke action in the CS1810xx/CS4961xx. To send a
message, the host optionally writes to the A, B, and C registers. Writing to the D register
transmits the message to the CS1810xx/CS4961xx. A listing of all HMI messages is
shown in Tab l e 4. Refer also to "HMI Definitions" on page 33 and "HMI Access Code" on
page 34.
Table 4. HMI messages
Message
DRQ Handshake
Mode
A B C D
Translate Address n/c Address (MS) Address Address (LS) 0xB3
Acknowledge Interrupt n/c n/c n/c n/c 0xB4
Identify read n/c n/c 7 0xB5
Goto Packet Transmit
Buffer
write n/c n/c 6 0xB5
Goto Translation write n/c n/c 5 0xB5
Acknowledge Packet
Receipt
n/c n/c n/c 4 0xB5
Transmit Packet n/c n/c n/c 3 0xB5
Goto Counters read n/c n/c 2 0xB5
Goto Packet Receive
Buffer
read n/c n/c 1 0xB5
Goto Translation read n/c n/c 0 0xB5