Owner's manual

14 ©Copyright 2005 Cirrus Logic, Inc. DS651UM23
Version 2.3
CobraNet Hardware User’s Manual
Pinout and Signal Descriptions
4.2.5 Miscellaneous Signals
4.2.6 Power and Ground Signals
Signal Description Direction
CM-2
Pin #
CS1810xx/
CS4961xx Pin #
Notes
HRESET Reset In J1:A18 93
System reset (active low).
10 ns max rise time. 1 ms min assertion time.
WATCHDOG Watch Dog Out J3:A17 95
Toggles at 750 Hz nominal rate to indicate proper
operation. Period duration in excess of 200 ms
indicates hardware or software failure has occurred
and the interface should be reset. Note that
improper operation can also be indicated by short
pulses (<100 ns).
MUTE
Interface
Ready
Out J3:A2 92
Asserts (active low) during initialization and when a
fault is detected or connection to the network is lost.
NC No Connect - -
28, 50-53, 78-
81, 141, 142
Signal Description CM-2 Pin #
CS1810xx/CS4961xx
Pin #
Specification
VCC_+3V
System Digital +3.3 v
J1:B20, B17, B15,
B13, B11, B9, B7,
B5, B3
J3:B14, B12, B10,
B8, B6, B4, B2
N/A
3.3
± 0.3v, 500 mA Typ., 750 mA Max.
VCC
_+5V
J3;B[18:17] N/A Backwards Compatibility
VDDD N/A
10, 24, 54, 66, 83,
98, 119, 130
+1.8 V @ 500mA Typ. for Core Logic
VDDIO N/A
18, 33, 44, 60, 73,
91, 113, 136
+3.3 V @ 120mA Typ. for I/O Logic
VDDA N/A 129 Filtered +1.8 V @ 10mA Typ.
AUX_POWER
[3-0]
J3:B[20:19],
A[20:19]
N/A
GND Digital Ground
J1:B19, B16, B14,
B12, B10, B8, B6,
B4, B2
J3:B16, B15, B13,
B11, B9, B7, B5,
B3, B1
13, 21, 27, 36, 47,
57, 63, 69, 76, 86,
94, 101, 116, 122,
126, 133, 139