3.3 Power Line Calibration Characteristics
Typical characteristics conditions:
•T
A
=25ºC, V
DD
= 12V, GND = 0V
• All voltages are measured with respect to GND.
• Unless otherwise specified, all current is positive when
flowing into the IC.
Minimum/Maximum characteristics conditions:
T
J
=25ºC, V
DD
= 11V to 17V, GND = 0V
Notes: 6. The CS1630/31 supports leading-edge phase-cut waveforms only for power line calibration.
7. Range is recommended for power line calibration operation only.
Parameter (Note 6) Min Typ Max Units
Input Line Frequency (Note 7) 47 50/60 63 Hz
Input Voltage (Note 7)
CS1630
CS1631
114
218
120
230
126
242
V
V
Dual-bit 00 (“00”) 24 34 44 Degrees
Dual-bit 01 (“01”) 52 62 72 Degrees
Dual-bit 10 (“10”) 108 118 128 Degrees
Dual-bit 11 (“11”) 136 146 156 Degrees
Special Character (SC) 80 90 100 Degrees