User Manual

CRD1680-7W
DS1017RD3 15
6.1 120VAC Dimmer Compatibility
Table 1 reports the empirical dimmer compatibility results when detectable inputs to the dimmer compatibility circuit are generated using a 120VAC
transformer paired with a leading-edge or trailing-edge dimmer.
Table 1: 120VAC, 60Hz Mains Power System
Dimmer
1
Lutron DVLV-600P
Leading Edge
Lutron DVELV-300P
Trailing Edge
Lutron SELV-300P
Trailing Edge
Levitron 6615
Trailing Edge
Flicker Free
2
Steady-State
I
out
(%)
Min
Flicker Free
2
Steady-State
I
out
(%)
Min
Flicker Free
2
Steady-State
I
out
(%)
Min
Flicker Free
2
Steady-State
I
out
(%)
Min
Max Max Max Max
Transformer
3
# of lamps # of lamps # of lamps # of lamps # of lamps # of lamps # of lamps # of lamps
136 1 3 6 136 1 3 6 136 1 3 6 136 1 3 6
Hatch
LS1250EN
YYY
5.2 5.2 5.2
---
---
---
---
---
---
808070 --- --- ---
Lightech
LET60
YYY
5.2 5.2 5.2
YYY
5.2 5.2 5.2
YYY
5.2 5.2 5.2
YYY
20 10 5.2
100 100 100 100 100 90 100 100 80 100 100 100
Hatch
RS12-80M
YYY
5.2 5.2 5.2
YYY
5.2 5.2 5.2
YYY
5.2 5.2 5.2
YYY
30 10 10
100 100 100 100 100 100 100 100 80 100 100 100
Hatch
VS12-60WD
YYY
5.2 5.2 5.2
YYY
5.2 5.2 5.2
YYY
5.2 5.2 5.2
YYY
10 5.2 5.2
100 100 100 100 100 80 100 90 80 100 100 90
Osram
ET-MZ 60
YYN
5.2 5.2 5.2
YYY
5.2 5.2 5.2
YYY
5.2 5.2 5.2
YYY
10 5.2 5.2
100 100 100 100 100 70 100 90 70 100 100 80
Eurofase Y N N
5.2 5.2 5.2
YYN
5.2 5.2 5.2
YYY
5.2 5.2 5.2
YYN
10 10 10
100 90 70 100 100 80 100 100 70 100 100 90
Notes: 1. This document includes trademarks, trade names, brands, logos, product names and/or product identifiers of companies other than Cirrus Logic, Inc. All such trademarks,
trade names, brands, logos, product names, and product identifiers are for identification purposes only and are the property of their respective owners, who are not
affiliated with Cirrus Logic. Please visit the respective sites of those owners to obtain a listing or understanding of their trademark rights. This document also includes
results from testing performed by Cirrus Logic for its own purposes and for which there are currently no industry standards. While this testing was applied objectively, its
results may include at least some degree of subjectivity. The testing or test results should not be interpreted as any comment on the overall quality or suitability of any
tested products.
2. Flicker-free results are reported at different conduction angle ranges and dependent on transformer and dimmer pairing.
3. Empirical results are recorded only with a magnetic transformer paired with a lead-edge dimmer.