Manual

CRD1610A-8W
DS1012RD3 15
7.2 Flyback Transformer
The flyback transformer stage is a quasi-resonant current-regulated DC-DC Converter capable of delivering the
highest possible efficiency at a constant current while minimizing line frequency ripple. The auxiliary winding is used
for zero-current detection and overvoltage protection.
7.2.1 Electrical Specifications
Characteristics conditions:
Operating temperature range: -25 °C to +120 °C (including coil heat)
Notes: 3. Time = 2s
4. Measured across pins 3 and 4
5. Measured across pins B and A
6. Measured across pins 2 and 1
Parameter Condition Sym Min Typ Max Unit
Flyback Transformer
Electrical Strength (Note 3) f
operate
=50/60Hz - 4 - kV
RMS
Primary Inductance (Note 4) f
resonant
=10kHz, 0.3V at
20°C
L
P
2.79 3.1 3.41 mH
Primary Leakage Inductance (Note 4) f
resonant
=10kHz, 0.3V at
20°C
L
K
--15H
Primary DC Resistance (Note 4)
t
DCR
=2C
2.175 2.90 3.625
Secondary DC Resistance (Note 5)
t
DCR
=2C
- - 0.22
Auxiliary DC Resistance (Note 6)
t
DCR
=2C
0.3975 0.53 0.6625
36T
#35AWG
(0.14mm)
52T
#35 AWG
(0.14 mm)
13 T
# 35AWG
(0.14mm)
Primary
4
5
3
1
Auxiliary
2
Secondary
13T
#32AWG
(0.20mm) ×2
B
A
Figure 11. Flyback Transformer Schematic