User guide

126 ©Copyright 2006 Cirrus Logic, Inc. DS651PM25
CobraNet Programmer’s Reference
Error Code Reference
9. Error Code Reference
9.1 Legend
Byte Code - Numeric error code. Error codes reported through SNMP or HMI are of
varying form must be converted to this common byte code representation as per
instructions give in section 9.2 below.
Flash Code - Code as reported in a fatal fault situation. Flash codes are typically only
displayed for fatal errors.
Type - Classification and behavior of the error condition.
Name - Name assigned to the error by the firmware programmer.
Description - Description of the error condition.
Expected Conditions - Foreseeable conditions under which the error condition would
occur on normally functioning and properly connected hardware.
Unexpected Conditions - Conditions indicating a hardware of firmware fault.
Table 17. Error Types
Type Description
TX Recoverable and expected transmit error
TXQUIET Informative transmit incident
TXFAULT Unexpected but recoverable transmit error
RX Recoverable and expected receive error
RXQUIET Informative receive incident
RXFAULT Unexpected but recoverable receive error
TXRX Recoverable and expected error simultaneously affecting transmit and receive
FAULT Unexpected but recoverable error
FATAL Unrecoverable error condition. Reported as a flash code on the fault indicator.