Manual
CDB5521/22/23/24/28
10 DS317DB2
Register Read Command (HEX) Write Command (HEX)
Offset Register Physical Channel 1 09 01
Offset Register Physical Channel 2 19 11
Offset Register Physical Channel 3 29 21
Offset Register Physical Channel 4 39 31
Offset Register Physical Channel 5 49 41
Offset Register Physical Channel 6 59 51
Offset Register Physical Channel 7 69 61
Offset Register Physical Channel 8 79 71
Gain Register Physical Channel 1 0A 02
Gain Register Physical Channel 2 1A 12
Gain Register Physical Channel 3 2A 22
Gain Register Physical Channel 4 3A 32
Gain Register Physical Channel 5 4A 42
Gain Register Physical Channel 6 5A 52
Gain Register Physical Channel 7 6A 62
Gain Register Physical Channel 8 7A 72
Configuration Register 0B 03
Conversion Data FIFO 0C ---
Channel Setup Registers 0D 05
Table 2. Microcontroller Read/Write Commands via RS-232
Perform Conversion Conversion Command (HEX)
Normal Conversion on Setup 1 80
Normal Conversion on Setup 2 88
Normal Conversion on Setup 3 90
Normal Conversion on Setup 4 98
Normal Conversion on Setup 5 A0
Normal Conversion on Setup 6 A8
Normal Conversion on Setup 7 B0
Normal Conversion on Setup 8 B8
Normal Conversion on Setup 9 C0
Normal Conversion on Setup 10 C8
Normal Conversion on Setup 11 D0
Normal Conversion on Setup 12 D8
Normal Conversion on Setup 13 E0
Normal Conversion on Setup 14 E8
Normal Conversion on Setup 15 F0
Normal Conversion on Setup 16 F8
Table 3. Microcontroller Conversion Commands via RS-232