User Manual
Table Of Contents
- Features
- Table of Contents
- List of Figures
- 1. Hardware
- 2. Software
- 2.1 Installation Procedure
- 2.2 Using the Software
- 2.3 Start-up Window
- 2.4 Connect Menu
- 2.5 System Menu
- 2.5.1 Setup Window
- 2.5.1.1 Refresh Screen Button
- 2.5.1.2 Reset DUT Button
- 2.5.1.3 Save Config and Load Config Buttons
- 2.5.1.4 CS5480 MCLK Frequency
- 2.5.1.5 Configuration Registers
- 2.5.1.6 Pulse Control Register
- 2.5.1.7 Pulse Width and Pulse Rate Registers
- 2.5.1.8 Phase Compensation
- 2.5.1.9 Integrator Gain, System Gain
- 2.5.1.10 Sample Count, Cycle Count, Settle Time
- 2.5.1.11 Epsilon
- 2.5.1.12 ZXNUM
- 2.5.1.13 Mask Register
- 2.5.1.14 Temperature Registers
- 2.5.1.15 Zero-crossing Level and No Load Threshold
- 2.5.1.16 V1/V2 Sag, V1/ V2 Swell, and I1/I2 Overcurrent Registers
- 2.5.1.17 Channel Selection Level, Channel Select Minimum Amplitude, and Voltage Fixed RMS Reference Registers
- 2.5.1.18 Register Checksum, SerialCtrl Registers
- 2.5.1 Setup Window
- 2.6 Calibration Window
- 2.7 Conversion Window
- 2.8 Cirrus Test Window
- 2.8.1 Data Collection Window
- 2.8.1.1 Time Domain / FFT/ Histogram Selector
- 2.8.1.2 Config Button
- 2.8.1.3 Collect Button
- 2.8.1.4 Output Button
- 2.8.1.5 Zoom Button
- 2.8.1.6 Channel Select Button
- 2.8.1.7 Output Button & Window
- 2.8.1.8 Configuration Window
- 2.8.1.9 Collecting Data Sets
- 2.8.1.10 Analyzing Data
- 2.8.1.11 Histogram Information
- 2.8.1.12 Frequency Domain Information
- 2.8.1.13 Time Domain Information
- 2.8.2 Data Collection to File Window
- 2.8.3 Setup and Test Window
- 2.8.1 Data Collection Window
- Appendix A. Bill Of Materials
- Appendix B. Schematics
- Appendix C. Layer Plots

CDB5480U
28 DS893DB5
number in the Samples to Average field. The user should stop continuous conversion before leaving this
window. The Continuous Conversion button should not be used with BAUD rates less than 1200 Hz in
UART mode. Using lower BAUD rates (including the default 600 baud) will result in overflowing the
communication buffer and cause other window errors and/or communication failure.
Data logging can be enabled using the DATALOG On/Off check box and Filename field.
2.7.3 Standby Mode Button
When this button is pressed, the CS5480 will enter a standby power saving mode. To return to normal
mode, press the Power Up button. The user should power up the device before leaving this window.
2.7.4 Power Up Button
The Power Up button is used to send the wake-up command to the CS5480. The CS5480 will return to
normal operating mode.
2.7.5 Line Frequency Result
When the AFC bit in the Config2 register is set, the Epsilon register will be calculated automatically by the
CS5480 and the Line Frequency fields will be updated automatically in continuous conversion mode. If
the AFC bit in the Config2 register is not set and the line frequency is other than the default value (50 Hz),
the line frequency must be set manually here to make Epsilon be the ratio of line frequency to the output
word rate (OWR). This ensures the accuracy of the quadrature power (Q1, Q2) and the reactive power
(Q1
AVG
and Q2
AVG
) calculations. Refer to the CS5480 data sheet for more details.
2.7.6 Temperature Result
The Temperature field displays the CS5480’s die temperature in the top right corner of the Conversion
window.
2.7.7 Samples to Average
The Samples to Average field allows the user to average a number of measurement results.