User Manual
Table Of Contents
- Features
- Table of Contents
- List of Figures
- 1. Hardware
- 2. Software
- 2.1 Installation Procedure
- 2.2 Using the Software
- 2.3 Start-up Window
- 2.4 Connect Menu
- 2.5 System Menu
- 2.5.1 Setup Window
- 2.5.1.1 Refresh Screen Button
- 2.5.1.2 Reset DUT Button
- 2.5.1.3 Save Config and Load Config Buttons
- 2.5.1.4 CS5480 MCLK Frequency
- 2.5.1.5 Configuration Registers
- 2.5.1.6 Pulse Control Register
- 2.5.1.7 Pulse Width and Pulse Rate Registers
- 2.5.1.8 Phase Compensation
- 2.5.1.9 Integrator Gain, System Gain
- 2.5.1.10 Sample Count, Cycle Count, Settle Time
- 2.5.1.11 Epsilon
- 2.5.1.12 ZXNUM
- 2.5.1.13 Mask Register
- 2.5.1.14 Temperature Registers
- 2.5.1.15 Zero-crossing Level and No Load Threshold
- 2.5.1.16 V1/V2 Sag, V1/ V2 Swell, and I1/I2 Overcurrent Registers
- 2.5.1.17 Channel Selection Level, Channel Select Minimum Amplitude, and Voltage Fixed RMS Reference Registers
- 2.5.1.18 Register Checksum, SerialCtrl Registers
- 2.5.1 Setup Window
- 2.6 Calibration Window
- 2.7 Conversion Window
- 2.8 Cirrus Test Window
- 2.8.1 Data Collection Window
- 2.8.1.1 Time Domain / FFT/ Histogram Selector
- 2.8.1.2 Config Button
- 2.8.1.3 Collect Button
- 2.8.1.4 Output Button
- 2.8.1.5 Zoom Button
- 2.8.1.6 Channel Select Button
- 2.8.1.7 Output Button & Window
- 2.8.1.8 Configuration Window
- 2.8.1.9 Collecting Data Sets
- 2.8.1.10 Analyzing Data
- 2.8.1.11 Histogram Information
- 2.8.1.12 Frequency Domain Information
- 2.8.1.13 Time Domain Information
- 2.8.2 Data Collection to File Window
- 2.8.3 Setup and Test Window
- 2.8.1 Data Collection Window
- Appendix A. Bill Of Materials
- Appendix B. Schematics
- Appendix C. Layer Plots

CDB5480U
DS893DB5 15
2. SOFTWARE
The evaluation board comes with software and a USB cable to link the evaluation board to the PC. The
evaluation software was developed with LabWindows
®
/CVI
®
, a software development package from Na-
tional Instruments. The evaluation software is designed to run with Windows XP™ and Windows 7™. The
following procedure is based on Windows XP.
2.1 Installation Procedure
Follow the steps below to install the GUI:
1. Access the following web site: http://www.cirrus.com/en/support
.
2. Navigate to the CDB5480U software link under Energy Measurement. The Software License web
page is displayed.
3. To agree with the terms and conditions, click the Agree button. The File Download window is dis-
played.
4. Click the Save button. The Save As window is displayed.
5. Select a location to store the compressed folder.
6. Click the Save button. The Download complete window is displayed.
7. Click the Open Folder button. The location where the compressed folder is stored is displayed.
8. Right-click on the compressed folder, and click Extract All.
9. Select a location to extract the files.
10. Navigate to the location where the extracted files are stored and double-click on the setup.exe file.
11. Click the Install button, and follow the installation instructions.
12. Execute the GUI using Section 2.1.1 Executing the GUI.
2.1.1 Executing the GUI
1. From the Start menu, click All Programs.
2. Click Cirrus Energy Measurement Evaluation (CDB5480U).
3. Click CDB5480U. The GUI is launched.
2.2 Using the Software
Before launching the software, check all jumper settings on the CDB5480U evaluation board as described
in “Evaluation Board Overview” on page 4, and connect the board to an open USB port on the PC using
the provided cable. Once the board is powered on, the software program can be launched.