Owner manual
Table Of Contents
- Features & Description
- Table of Contents
- List of Figures
- List of Tables
- 1. Initial Setup
- 2. Hardware Description
- 2.1 Block Diagram
- 2.2 Analog Hardware
- 2.3 Digital Hardware
- 2.4 Power Supplies
- 2.5 PCB Layout
- 3. Software Description
- 4. Bill Of Materials
- 5. Layer Plots
- 6. Schematics
- 7. Revision History

CDB5378
14 DS639DB4
• Once the Setup panel is set, select Configure on the Digital Filter sub-panel.
• After digital filter configuration is complete, click Capture to collect a data record.
• Once the data record is collected, the Analysis panel is automatically displayed.
• Select Noise FFT from the Test Select control to display the calculated noise statistics.
• Verify the noise performance (S/N) is 124 dB or better.
1.4.2 Distortion Test
• Set the controls on the Setup panel to match the picture:
• Once the Setup panel is set, select Configure on the Digital Filter sub-panel.
• After digital filter configuration is complete, click Capture to collect a data record.
• Once the data record is collected, the Analysis panel is automatically displayed.
• Select Signal FFT from the Test Select control to display the calculated signal statistics.
• Verify the distortion performance (S/D) is 112 dB or better.