Owner manual
CDB5376
DS612DB3 33
2.3.8 External Connector
Power supplies and telemetry signals route to a 20-pin double row connector with 0.1" spacing (J26). This
header provides a compact standardized connection to the CDB5376 external signals.
2.4 Power Supplies
Power is supplied to CDB5376 through banana jacks (J6, J7, J8, J9) or through the external connector
(J26). The banana jacks make separate connections to the EXT_VA-, EXT_VA+, GND, and EXT_VD
power supply nets, which connect to the analog and digital linear voltage regulator inputs. The external
connector makes separate connections only to the EXT_VA-, GND, and EXT_VA+ power supply inputs
and it is required to jumper EXT_VA+ to EXT_VD when powering CDB5376 from the external connector.
The EXT_VA-, EXT_VA+ and EXT_VD power supply inputs have zener protection diodes that limit the
maximum input voltages to +13 V or -13 V with respect to ground. Each input also has 100 uF bulk ca-
pacitance for bypassing and to help settle transients and another 0.01 uF capacitor to bypass high-fre-
quency noise.
2.4.1 Analog Voltage Regulators
Linear voltage regulators create the positive and negative analog power supply voltages to the analog
components on CDB5376. These regulate the EXT_VA+ and EXT_VA- power supply inputs to create the
VA+ and VA- analog power supplies.
Pins Name Signal
1, 2 CLK+, CLK- Clock Input
3, 4 SYNC+, SYNC- Synchronization Input
5, 6 SCL+, SCL- I2C Clock
7, 8 SDA+, SDA- I2C Data
9, 10 BYP_SDA+, BYP_SDA- I2C Data Bypass
11, 12 BYP_SCL+, BYP_SCL- I2C Clock Bypass
13, 14 TX, GND UART transmit
15, 16 RX, GND UART receive
17, 18 EXT_VA-, GND Negative Power Supply
19, 20 EXT_VA+, GND Positive Power Supply
Specification Value
Positive Analog Power Supply +2.5 V, +5 V
Low Noise Micropower Regulator - Linear Tech LT1763CS8
Surface Mount Package Type SO-8
Load Regulation, -40 C to +85 C +/- 25 mV
Quiescent Current, Current @ 100 mA Load
40 µA, 2 mA
Output Voltage Noise, 10 Hz - 100 kHz
20 µV
RMS
Ripple Rejection, DC - 200 Hz > 50 dB