User Manual

18 DS792DB1
CDB43L22
6. JUMPER SETTINGS
JMP LABEL PURPOSE POSITION FUNCTION SELECTED
J31 VL
Selects source of voltage for the
VL supply
*+1.8V Voltage source is +1.8 V regulator.
+2.5V Voltage source is +2.5 V regulator.
+3.3V Voltage source is +3.3 V regulator.
J36 VA_HP
Selects source of voltage for the
VA_HP supply
*+1.8V Voltage source is +1.8 V regulator.
+2.5V Voltage source is +2.5 V regulator.
J25 VA
Selects source of voltage for the
VA supply
*+1.8V Voltage source is +1.8 V regulator.
+2.5V Voltage source is +2.5 V regulator.
J28 VD
Selects source of voltage for the
VD supply
*+1.8V Voltage source is +1.8 V regulator.
+2.5V Voltage source is +2.5 V regulator.
J52
J47
J74
J53
VL
+VA_HP
VA
VD
Current Measurement
*SHUNTED 1 Ω series resistor is shorted.
OPEN 1 Ω series resistor in power supply path.
J48 VP Current measurement *SHUNTED VP supply to CS43L22 is selected.
J13
J14
[No Label]
Applies a filtered or a non-filtered
version of the SPKA- signal to J60
*1 - 2 SPKOUTA- output routed to J60.
2 - 3 SPKOUTA- output not routed to J60.
J16
J17
[No Label]
Applies a filtered or a non-filtered
version of the SPKA+ signal to J59
*1 - 2 SPKOUTA+ output routed to J59.
2 - 3 SPKOUTA+ output not routed to J59.
J11
J12
[No Label]
Applies a filtered or a non-filtered
version of the SPKB- signal to
J101
*1 - 2 SPKOUTB- output routed to J101.
2 - 3 SPKOUTB- output not routed to J101.
J20
J23
[No Label]
Applies a filtered or a non-filtered
version of the SPKA- signal to J99
*1 - 2 SPKOUTB+ output routed to J99.
2 - 3 SPKOUTB+ output not routed to J99.
J15 MONO
Applies a short between SPKOUT
A+ and A-. (Used only after
MONO function is enabled in the
CS43L22)
*OPEN
Channel A+ and A- to J59 and J60 respec-
tively.
SHUNTED
Channel + to J59 and J60 respectively.
J19 MONO
Applies a short between SPKOUT
B+ and B-. (Used only after
MONO function is enabled in the
CS43L22)
*OPEN
Channel B+ and B- to J99 and J101 respec-
tively.
SHUNTED Channel - to J99 and J101 respectively.
J3 HP B LOAD
Selects 32 or 16 Ω load for
HP/LINE_OUTB (DAC out)
1 - 2 16 Ω load selected.
2 - 3 32 Ω load selected.
J9 HP A LOAD
Selects 32 or 16 Ω load for
HP/LINE_OUTA (DAC out)
1 - 2 16 Ω load selected.
2 - 3 32 Ω load selected.
J1 LEFT CH
Selects between a filtered or non
filtered version of the
HP/LINE_OUTA signal.
1 - 2 Non-filtered HP/LINE_OUTA to HP/Line Jack.
*2 - 3
Filtered HP/LINE_OUTA to HP/Line Jack.
J2 RIGHT CH
Selects between a filtered or non
filtered version of the
HP/LINE_OUTB signal.
1 - 2 Non-filtered HP/LINE_OUTA to HP/Line Jack.
*2 - 3
Filtered HP/LINE_OUTA to HP/Line Jack.
J22 HP DETECT
Selects the control source for the
SPKR/HP pin
1 - 2 FPGA.
*2 - 3 HP Jack.
J34 Board Power
Selects either USB or External
+5 V power for the board
1 - 2 External +5 V power.
*2 - 3
USB generated +5 V power. (USB hub must be
capable of greater than 300 mA)
J5 VP
Selects either External or Battery
power for VP and for the buck reg-
ulators that powers VA, VA_HP
and VD
*1 - 2 External from J35.
2 - 3
Battery from BT1-BT3 (bottom side)
Table 5. Jumper Settings