Instruction Manual

AN400
12
1. Tested at nominal input voltage, nominal input frequency and without a dimmer after soaking for 15 minutes
2. Average
3. Peak-to-peak
4. Measured with Chroma 66202 Power Analyzer
5. This document includes trademarks, trade names, brands, logos, product names and/or product identifiers of companies other
than Cirrus Logic, Inc. All such trademarks, trade names, brands, logos, product names, and product identifiers are for
identification purposes only and are the property of their respective owners, who are not affiliated with Cirrus Logic. Please visit
the respective sites of those owners to obtain a listing or understanding of their trademark rights. This document also includes
results from testing performed by Cirrus Logic for its own purposes and for which there are currently no industry standards. While
this testing was applied objectively, its results may include at least some degree of subjectivity. The testing or test results should
not be interpreted as any comment on the overall quality or suitability of any tested products
Lutron RRD-10ND
Leading Edge
YY 252 9
Lutron RRD-3LD
Leading Edge
YY 252 9
Lutron S-600
Leading Edge
YY 252 9
Lutron SCL-153
Leading Edge
YY 251 9
Lutron TTCL-100
Leading Edge
YY 252 9
Dimmer
5
Flicker Free
Steady-State
Monotonic
Dimming
Max I
out
(mA) Min I
out
(mA)
Manufacture Type
# of lamps # of lamps # of lamps # of lamps
11 1 1