ACCUMULATE MULTIPLE PF READING AND CONFIRM
(See Figure 39.)
SDI = 0x90 0x15 0xFFFFFF Read PF1 (page 16, register 21)
SDO = 0xFF 0xFF 0x410F40 (0.508278)
SDI = 0x90 0x19 0xFFFFFF Read PF2 (page 16, register 25)
SDO = 0xFF 0xFF 0x4106A8 (0.5080157)
For 1 to Count {
PF1SUM = PF1SUM + PF1
PF2SUM = PF2SUM + PF2}
PF1AVG = PF1SUM ÷ Count
PF2AVG = PF1SUM ÷ Count
Figure 39. Conversion Window
PHASE COMPENSATION COMPLETE
(RETURN CPCC & FPCC to MAIN)
ACCUMULATE MULTIPLE
PF READING AND
CONFIRM PF = 0.5