Bridge Commands
Command Description
help
Displays help screen for command
access <accesscode>
Sets access code to allow slave CR-SEH onto to
Master’s network. Slave accesscode must match
accesscode of desired Master
filter [disable, bcast,
mcast, show]
Selects filtering operation and level.
login [enable|disable]
Enables/disables accesscode/password login
authentication. Must be set in master and slave
master
Sets CR-SEH as Master bridge
password <pwrd>
Sets login password. Slave password must match
password of desired Master CR-SEH
slave
Sets CR-SEH as Slave bridge (default)
bridge
status
(Master only)
Displays status of active connections
access Sets the accesscode portion of the accesscode/password pair to allow slave CR-SEHs
to connect to a master CR-SEH.
accesscode must match the accesscode in the master
CR-SEH.
filter Selects Ethernet traffic filtering mode.
filter disable turns filtering off. filter bcast filters out broadcast and multicast
packet while
filter mcast filters out just multicast packets. filter show displays the
filter settings.
login Turns the authentication login requirement off and on. When on, Enabled, an accesscode and
password must be entered in the slave CR-SEH that matches the accesscode and password of
the master CR-SEH with which the slave CR-SEH wants to establish a connection. Note that
the network number of the CR-SEHs must also agree. See the section Radio Commands for
details on the network number. This feature prevents unauthorized CR-SEHs from
connecting to a CR-SEH network.
master Sets the CR-SEH as the Master CR-SEH.
password Sets the
password portion of the accesscode/password pair to allow slave CR-SEHs to
connect to a master CR-SEH. Password must match the password in the master CR-SEH.
slave Sets the CR-SEH as a Slave CR-SEH.
status Displays the status of active slave CR-SEH connections. (Only available in the master CR-
SEH.)