Specifications
Sicon-8 Technical Manual CircuitWerkes, Inc.
77
Function: Relay_OperateLower
Parameters: param1, param2
Returns: Nothing
param1 = channel number (1 – 32)
param2 = milliseconds
Example: Relay_OperateLower 5, 300
Press raise button on channel 5 and hold it pressed for 300 milliseconds (0.3 seconds)
*************************************************************************************************
Function: Relay_EnableRaise
Parameters: param1
Returns: Nothing
param1 = channel number (1 – 32)
Example: Relay_EnableRaise(1) = 1
Enable operation of the raise button on channel 1.
Function: Relay_EnableLower
Parameters: param1
Returns: Nothing
param1 = channel number (1 – 32)
Example: Relay_EnableLower(3) = 0
Disable operation of the lower button on channel 3.
*************************************************************************************************
Function: Relay_GetRaiseState
Parameters: param1
Returns: Boolean
param1 = channel number (1 – 32)
Example: Relay_GetRaiseState(1)
Read raise relay state of channel 1. If relay is closed, 1 (true) is returned and if opened, 0 (false) is returned.
*************************************************************************************************
Function: Relay_GetLowerState
Parameters: param1
Returns: Boolean
param1 = channel number (1 – 32)
Example: Relay_GetLowerState(3)
Read lower relay state of channel 3. If relay is closed, 1 (true) is returned and if opened, 0 (false) is returned.
*************************************************************************************************