Specifications

TEST PORT
Connector Type 15 position, female 3 tier D-sub
Function Programmable I/O and voltage
output (optional interface)
AUXILIARY IF INPUT
Connector Type High-density dual inline
Function External digital receiver input
(optional interface)
AC POWER REQUIREMENTS
ENVIRONMENTAL/SAFETY
DIMENSIONS AND WEIGHT
GENERAL CHARACTERISTICS
OPTIONAL SYSTEMS
P25 (OPTIONAL)
RF SIGNAL GENERATOR
RF RECEIVER
P25 MEASUREMENTS
LCD DISPLAY Screen Size 6.4” diagonal
162.6 mm diagonal
Active Area 5.1” (h) x 3.8” (v)
129.6 mm (h) x 97.44 mm (v)
Resolution 640 x 480 pixels
Disk Storage Internal 30 GByte hard disk
available for user storage
Height 7.75” (19.7 cm)
Width 14” (35.6 cm)
Depth 20.5” (52.0 cm)
Weight 36.8 lbs. (16.5 kg)
LCD Display Screen Size 6.4” diagonal (162.6 mm
diagonal)
OPERATING TEMPERATURE 0 to 50°C (Tested in accordance
with MIL-PRF-28800F Class 3)
WARM-UP TIME 15 minutes
STORAGE TEMPERATURE -40 to 71°C (Tested in
accordance with MIL-PRF-
28800F Class 3)
RELATIVE HUMIDITY 80% up to 31°C decreasingly
linearly to 50% at 40°C (Tested
in accordance with MIL-PRF-
28800F Class 3)
ALTITUDE 4,000 m (13,123 ft)
(MIL-PRF-28800F Class 3)
SHOCK AND VIBRATIONS 30 G Shock (functional shock)
5-500 Hz random vibrations
(Tested in accordance with
MIL-PRF-28800F Class 3)
USE Pollution degree 2
EMC EN 61329, Class A
RELIABILITY >8,000 hour calculated MTBF
(MIL-HDBK-217F, notice 2)
Safety Standards UL 61010B-1
EN 61010-1
CSA C22.2 No.61010-1
Voltage 100 V to 120 VAC @ 60 Hz
220 V to 240 VAC @ 50 Hz
Power Consumption Nominally 120 W (200 W Max)
Mains Supply Voltage
Fluctuations
≤10% of the nominal voltage
Fuse Requirements 3 A, 250 V, Type F
FREQUENCY
Range 10 MHz to 1.05 GHz
(standard) (Usable from
100 kHz)
10 MHz to 2.7 GHz
(392XOPT058) (Usable from
100 kHz)
Resolution 1 Hz
Accuracy Frequency standard ±1 count
OUTPUT LEVEL
Range T/R Port: -138.0 to -30.0 dBm
for C4FM and H-CPM modula-
tions (-40.0 for all other modu-
lations)
Gen Port: -130.0 to +10.0
dBm for C4FM and H-CPM
moduations (+0.0 dBm for all
other modulations)
Resolution 0.1 dB
Accuracy 1.0 dB for levels >-110 dBm
(Typical better than 0.6 dB)
1.5 dB for levels ≤-110
(Typical better than ±1.0 dB)
Modulation C4FM, CQPSK, LSM
Test Patterns STD 1011, STD CAL, STD
SILENCE, STD INTFR, STD
BUSY, STD IDLE, STD 511
(O.153), STORED SPCH, VOICE,
1011, SILENCE
Frequency Range 10 MHz to 1.05 GHz (standard)
(Usable from 100 kHz)
10 MHz to 2.7 GHz
(392XOPT058) (Usable from
100 kHz)
Resolution 1 Hz
Level Range T/R Port: -10 to +50 dBm
ANT Port: -60.0 to +10 dBm
(with preamp -63)
MODULATION FIDELITY
Range 0 to 20%
Resolution 0.01%
Accuracy <5.0% of reading (2.5 to 10%)
SYMBOL DEVIATION
Range 1500 Hz to 2100 Hz
Resolution 0.1 Hz
Accuracy ±10 Hz (1620 to 1980 Hz)
SYMBOL CLOCK ERROR
Range ±1000 mHz
Resolution 0.01 mHz
Accuracy 1 ppm (±48 mHz)
18