Specifications

Tx Ref Oscillator
Tx Power
Tx Modulation Balance
Tx BER
Tx FSK Error
Tx Magnitude Error
Tx Symbol Deviation
Technisonics Type 1 Radio Auto-Test/Alignment
(390XOPT614)
This option adds the capability to complete a fully automatic test and
alignment on Technisonics Type 1 radios. This option provides the
same functionality of the ASTRO Series radio Auto-Test/alignment
software, but for the Technisonics Type 1 radios.
Technisonics Type 2 Radio Auto-Test/Alignment
(390XOPT615)
This option adds the capability to complete a fully automatic test and
alignment on Technisonics Type 2 radios. This option provides the
same functionality of the ASTRO 25 Series radio Auto-Test/align-
ment software, but for the Technisonics Type 2 radios.
TX Tests
• Frequency
• Power
• CTCSS
Microphone sensitivity
Modulation limiting
Audio distortion
Audio frequency response
FM hum and noise
RX Tests
Audio distortion
Audio sensitivity
Audio frequency response
• Usable sensitivity
Displacement bandwidth
Audio squelch sensitivity
Audio squelch blocking
Hum and noise
Test High/Low or both power level settings on any channel with
support for a PTT line to auto-key/de-key the transmitter. Single
channel test execution is allowed to re-check failed channels. Supports
re-test, accept failure or abort on any failed test. Supports store and
recall for test configurations and test results. Network or local printer
support allows for an immediate hard copy to be obtained.
DMR Repeater Auto-Test (390XOPT626)
With the DMR repeater auto-test, the 3920B can automatically
perform the key transmitter and receiver tests for DMR Repeaters.
This test does not require the DMR repeater to be in any special test
mode, but can quickly make these measurements on any channel pro-
grammed into the repeater. The user simply indicates the frequencies
that the repeater is using from the auto-test setup screen, and then
can initiate the test and walk away. The testing is all performed com-
pletely automatically
SPECIFICATION
RF SIGNAL GENERATOR
SPECTRAL PURITY
FREQUENCY
Range 10 MHz to 1.05 GHz (Standard) (Usable from
100 kHz)
10 MHz to 2.7 GHz (392XOPT058) (Usable
from 100 kHz)
Resolution 1 Hz
Accuracy Frequency standard ±1 count
OUTPUT LEVEL
Range T/R Port: -130.0 to -30.0 dBm (-30 dBm max
for CW or FM; -35 dBm max for AM modula-
tions; -40 dBm max for complex modulations)
Duplex: -130.0 to +10.0 dBm (+10 dBm max
for CW or FM; +5 dBm max for AM modula-
tions; 0 dBm max for complex
modulation)
Resolution 0.1 dB
Accuracy 1.0 dB for levels >-110 dBm (Typical better
than 0.6 dB)
1.5 dB for levels ≤-110 dBm (Typical better
than 1.0 dB)
Residual FM <5 Hz (300 Hz to 3 kHz bandwidth)
Residual AM <0.1% RMS (300 Hz to 3 kHz bandwidth)
Harmonics <-25 dBc (Typically -30 dBc, RF level set at
+10 dBm)
Non-Harmonics <-55 dBc (all freq. except Crossovers)
<-35 dBc (At 2nd order crossover frequency)
(10 MHz to 1 GHz: Crossover = 1400 MHz -
Gen freq.)
(1 GHz to 2.7 GHz: Crossover = 3400 MHz -
Gen freq.)
(Tracking Gen: Crossover = 3410.7 MHz -
Gen freq.)
Phase Noise <-110 dBc/Hz @ 10 kHz offset, RF <500
MHz)
<-106 dBc/Hz @ 10 kHz offset, RF 1000
MHz)
<-95 dBc/Hz @ 10 kHz offset, RF >1000
MHz
12