Specifications
12
See our web site for a full catalog: www.navair.com
NAVAIR
TECHNOLOGIES
Programmable Measuring
❑ Frequency Range 10 µHz…25 MHz [50 MHz]
❑ Output Voltage 5 mVpp…10 Vpp (into 50 Ω) DC Offset ±5 mV…5 V
❑ Arbitrary Waveform Generator: 250 MSa/s, 14 Bit, 256 kPts
❑ Sine, Square, Pulse, Triangle, Ramp, Arbitrary Waveforms incl. Standard Curves
(white Noise, Cardiac etc.)
❑ Total harmonic Distortion 0.04 % (f <100 kHz)
❑ Burst, Sweep, Gating, external Trigger
❑ Rise Time <8 ns, in Pulse Mode 8…500 ns Variable-Edge-Time
❑ Pulse Mode: Frequency Range 100 µHz…12.5 MHz [25 MHz], Pulse Width
15 ns…999 s, Resolution 5 ns
❑ Modulation Modes AM, FM, PM, PWM, FSK (int. and ext.)
❑ 10 MHz Timebase: ±1 ppm TCXO, rear I/O BNC Connector
❑ Front USB Connector: Save and Recall of Waveforms and Settings
❑ 8.9 cm (3.5”) TFT: crisp Representation of the Waveform and all Parameters
❑ USB/RS-232 Dual-Interface, optional Ethernet/USB or IEEE-488 (GPIB)
❑ Basic Accuracy 0.05 %
❑ Measurement Functions L, C, R, |Z|, X, |Y|, G, B, D, Q, , , M, N
❑ Test Frequencies 20 Hz…200 kHz
❑ Up to 12 Measurements per Second
❑ Parallel and Series Mode
❑ Binning Interface HO118 (optional) for automatic Sorting of Components
❑ Internal programmable Voltage and Current Bias
❑ Transformer Parameter Measurement
❑ External Capacitor Bias up to 40 V
❑ Kelvin Cable and 4-Wire SMD Test Adapter included in Delivery
❑ Galvanically isolated USB/RS-232 Interface, optional IEEE-488 (GPIB)
❑ 6½-Digit Display (1,200,000 Counts)
❑ Resolution: 100 nV, 100 pA, 100 µΩ, 0.01 °C/F
❑ DC Basic Accuracy 0.003 %
❑ 2-Wire/4-Wire Measurements
❑ Measurement Intervals adjustable from 0.1…60 s
❑ Up to 100 Measurements per Second transmitted to a PC
❑ True RMS Measurement, AC and DC+AC
❑ Mathematic Functions: Limit Testing, Minimum/Maximum, Average and Offset
❑ Temperature Measurements with Platinum (PT100/PT1000) and Ni (K and J types) Sensors
❑ Internal Data Logger for up to 32,000 Measurement Results
❑ Offset Correction
❑ Galvanically isolated USB/RS-232 Interface, optional IEEE-488 (GPIB)
❑ [HM8112-3S]: HM8112-3 incl. Scanner
❑ Measurement Range 0 Hz…3 GHz
❑ 2 Measurement Inputs DC…200 MHz, 1 Measurement Input 100 MHz…3 GHz
❑ Input Impedance A/B: 1 MΩ/50 Ω (switchable), Sensitivity 25 mVrms
❑ Input Impedance C: 50 Ω, Sensitivity 30 mVrms
❑ 400 MHz Time Base with 0.5 ppm Stability
❑ 10-Digit Resolution at 10 s Gate Time
❑ 9 Measurement Functions, external Gate and Arming
❑ Input for external Time Base (10 MHz)
❑ Standard: TCXO (Temperature Stability: ±0.5 x 10-6) Optional: OCXO (Temperature
Stability: ±1 x 10-8)
❑ Intuitive One-Pushbutton Operation. Each Function directly Addressable
❑ Galvanically isolated USB/RS-232 Interface, optional IEEE-488 (GPIB)
25MHz [50MHz] Arbitrary
Function Generator
HMF2525 [HMF2550]
200kHz LCR-Bridge
HM8118
6½ – Digit Precision Multimeter
HM8112-3 [HM8112-3S]
3GHz Programmable Counter
HM8123