5-3 Connect the red test lead to the anode and the black test
lead to the cathode of the diode to be tested.
5-4 The approximate forward voltage drop of the diode will
be displayed in mV. If the connection is reversed “1”
will be displayed.
6 CONTINUITY TEST
7 BATTERY TEST
WARNING: Remove all power from the circuit being
tested when checking continuity. Discharge any charged
capacitors. Never connect the probes to any voltage
while the selector is set to .
6-1 Plug the black test lead into the COM jack and red test
lead into the V jack
6-2 Set the function switch to .
6-3 Connect the probes across the circuit to be measured.
6-4 If the resistance is lower than about 50Ω, the buzzer
will sound.
7-1 Plug the black test lead into the COM jack and red test
lead into the V jack
7-2 Set the function switch to desired BATT range position
(1.5V or 9V).
7-3 Connect the test leads to the two terminals of the battery
to be measured and note the reading.