User`s manual

– 10 –
For maximum accuracy it is recommended that the conductor passes
through the centre of the clamp head opening (use the centering marks
on the jaws as a guide).
Apply power to the AC line being measured.
Read the displayed current indicated with proper decimal point and
symbols.
Open clamp jaws and release.
5. RESISTANCE MEASUREMENT
WARNING: REMOVE ALL POWER FROM CIRCUIT BEING TESTED WHEN CHECKING
RESISTANCE. DISCHARGE ANY CHARGED CAPACITORS. NEVER CONNECT THE PROBES
TO ANY VOLTAGE WHILE THE FUNCTION IS SET TO
/ .
Plug the red test lead into / jack and the black test lead into COM
jack.
Press the Power button.
ʻ400.0ʼ, and and will appear on the display with the digit ʻ4ʼ flashing.
Press
/
pushbutton once, M will now appear on the display.
Apply the test leads to the circuit to be measured.
Read the displayed resistance with proper decimal point and symbols
( or K or M ).
6. CONTINUITY TEST
WARNING: REMOVE ALL POWER FROM CIRCUIT BEING TESTED WHEN CHECKING
CONTINUITY. DISCHARGE ANY CHARGED CAPACITORS. NEVER CONNECT THE PROBES TO
ANY VOLTAGE WHILE THE FUNCTION IS SET TO
/ .
Plug the red test lead into / jack and the black test lead into COM
jack.
Press the Power button.
ʻ400.0ʼ, and and will appear on the display with the digit ʻ4ʼ flashing.
Touch the test probe tips to the circuit or wire you wish to check.
If the resistance is less than 36 , the audible signal will sound. The display
will also show the actual resistance in ohms with proper decimal point.
NOTE: The display will read up to a maximum of 400 ohms in Continuity mode.