User`s manual
– 10 –
For maximum accuracy it is recommended that the conductor passes
through the centre of the clamp head opening (use the centering marks
on the jaws as a guide).
➔ Apply power to the AC line being measured.
➔ Read the displayed current indicated with proper decimal point and
symbols.
➔ Open clamp jaws and release.
5. RESISTANCE MEASUREMENT
WARNING: REMOVE ALL POWER FROM CIRCUIT BEING TESTED WHEN CHECKING
RESISTANCE. DISCHARGE ANY CHARGED CAPACITORS. NEVER CONNECT THE PROBES
TO ANY VOLTAGE WHILE THE FUNCTION IS SET TO
/ .
➔ Plug the red test lead into / jack and the black test lead into COM
jack.
➔ Press the Power button.
➔ ʻ400.0ʼ, and and will appear on the display with the digit ʻ4ʼ flashing.
➔ Press
/
pushbutton once, M will now appear on the display.
➔ Apply the test leads to the circuit to be measured.
➔ Read the displayed resistance with proper decimal point and symbols
( or K or M ).
6. CONTINUITY TEST
WARNING: REMOVE ALL POWER FROM CIRCUIT BEING TESTED WHEN CHECKING
CONTINUITY. DISCHARGE ANY CHARGED CAPACITORS. NEVER CONNECT THE PROBES TO
ANY VOLTAGE WHILE THE FUNCTION IS SET TO
/ .
➔ Plug the red test lead into / jack and the black test lead into COM
jack.
➔ Press the Power button.
➔ ʻ400.0ʼ, and and will appear on the display with the digit ʻ4ʼ flashing.
➔ Touch the test probe tips to the circuit or wire you wish to check.
➔ If the resistance is less than 36 , the audible signal will sound. The display
will also show the actual resistance in ohms with proper decimal point.
NOTE: The display will read up to a maximum of 400 ohms in Continuity mode.