Technical information
Easy Automotive Modules
Evaluation Kit EASYKIT AUX DRIVES (FS50R07W1E3_B11A)
CAN Messages
Application Note 60 AN2012-10
Evaluation Kit EASYKIT AUX DRIVES (FS50R07W1E3_B11A)
Direction
Msg.-
name,
ID,
DLC
Update
cycle
Bit -
offset |
length
Signal name Categorie Format
Possible
range refer
to unit
[Min|Max]
Description Reaction
0|1 SelfTest self test is active self test in progress
1|1 SglPulse
single pulse mode is active
(Mode 3)
single pulses on low side
switches according CAN
commands
2|1 Ready
all things okay and waiting
for enable (in Mode 2)
low side switches on
3|1 Run PWM output active PWM output active
4|1 Stop
DCL voltage out of operating
range OR internal failure
low side switches on
5|1 Error repetitive internal failures all switches off
8|1 Enabled
Mode 1: every time active
Mode 2 and 3: feedback of
CAN command
precondition for active
PWM output
9|1 Switch1
Switch1 µC input line is on
high level
if active → Mode 1
if passive → Mode 2 or 3
10|1 Switch2
Switch2 µC input line is on
high level
not used
11|1 CanInputActive
values received from CAN
will be considered
Mode 2 or Mode 3 active
12|4
16|1 STestFailed self test repetitive failed
17|1 VDclRepet repetitive VDclHigh event
18|1 IUVWHighRepet repetitive IxHigh event
19|1 HwFltRepet repetitive HwFault event
20|1 VauxRepet repetitive Vaux event
21|11
32|1 TNtcMax T_NTC > 110 °C
33|1 TPcbMax T_PCB > 100 °C
34|1 VDclHigh V_DCL > 420 V
35|1 VDclLow V_DCL < 25 V
36|1 IUHigh I_U_IGBT > 54 A
37|1 IVHigh I_V_IGBT > 54 A
38|1 IWHigh I_W_IGBT > 54 A
39|1 HwFault
HW trip from supply voltage
or overcurrent
or overvoltage
or overtemperature
40|1 Vaux
Ref_1V95 < 1.8 V
or Ref_1V95 > 2.1 V
41|23
Error state
Stop state
FsEasyKit
2Can
[0|1]
bit
bit
[0|1]
not used
state
(control
state
machine)
bit
general
[0|1]
write
cycle 1
ms
Fast-
Binary,
020h,
8
error event
stop event
not used
not used