Technical information
Easy Automotive Modules
Evaluation Kit EASYKIT AUX DRIVES (FS50R07W1E3_B11A)
CAN Messages
Application Note 59 AN2012-10
Evaluation Kit EASYKIT AUX DRIVES (FS50R07W1E3_B11A)
9 CAN Messages
Direction
Msg.-
name,
ID,
DLC
Update
cycle
Bit -
offset |
length
Signal name Categorie Format Unit
Possible
range refer
to unit
[Min|Max]
Description Reaction
0|1 DEnable DC/AC enable
if active → run starts in
Mode 2 OR
on positive edge → single
pulse activation in Mode 3
1|1 DSelftest
selftest demand with
possibility to reset ERROR
state
on positive edge → control
state machine processes
selftest
2|1 DSglPulse single pulse mode if active → Mode 3
3|1 DSglPulseULs
low side switch phase U
selection
if active → single pulse will
activate phase U low side
switch
4|1 DSglPulseVLs
low side switch phase V
selection
if active → single pulse will
activate phase V low side
switch
5|1 DSglPulseWLs
low side switch phase W
selection
if active → single pulse will
activate phase W low side
switch
6 |9
16|16 DSglPulseLength
unsigned
short
µs Q0 [0|65535] single pulse duration
target value for single pulse
length in Mode 3
32|16 DFacSet
signed
short
Hz Q6
[-512|
511.98]
AC output frequency target value in Mode 2
48|16
0|16 PFacNom
signed
short
Hz Q6
[0|
1023.98]
nominal AC output
frequency
nominal value for ramp up
function in Mode 2 (a target
value above will not further
increase the output voltage)
16|16 PVacNom
unsigned
short
V Q4
[0|
4095.94]
nominal AC output voltage
line to line
nominal value for ramp up
function in Mode 2 (will be
reached at nominal output
frequency)
32|32
012h, 8
013h, 8
prepared for later enhancements
prepared for later enhancements
not used
not used
analog set
value
parameter
value
not used
command
bit
[0|1]
Can2
FsEasyKit
De-
mand,
010h,
8
read
cycle
1 ms
Param,
011h,
8
read
cycle
1 ms